FiT FiT333 Manual

Professional breath alcohol analyzer
Hide thumbs Also See for FiT333:

Advertisement

Quick Links

IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell
in human mouth, etc...) may affect the Blood Alcohol Concentration (BAC) level, so
the Readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this
unit.
DO NOT drink before you drive!
Professional Breath Alcohol Analyzer
FiT333
www.group-fit.com
With Fuel Cell Sensor

Advertisement

Table of Contents
loading

Summary of Contents for FiT FiT333

  • Page 1 Professional Breath Alcohol Analyzer With Fuel Cell Sensor FiT333 IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc…) may affect the Blood Alcohol Concentration (BAC) level, so the Readings are For Reference Only. Neither the reseller nor manufacturer accept any liability arising from the use of this unit.
  • Page 2: Table Of Contents

    Measuring instrument……………………………………………………………………..3 What is What?........................4 Basic Scientific Principles…………………………………………………......5 Maintenance…………………………………………………………………………….….5 Intended Use………………………………………………………………………….…..5 Preparation…………………………………………………………..……………….……6 Power up…………………………………………………………………………….…..6 Operation instructions…………………………………………………………….…..…..7 Quick start……………………………………………………………..……………..…..7 Alcohol Menu……………………………………………………….……………...….…..8 System setting…………………………………………………….…………………...…..9 Misc………………………………………………………………………………….…..10 Especially low temperature operarion…………………………………………….…..10 Accessory………………………………………………………………………….….…..11 Specification…………………………………………………………………...………….11 Calibration…………………………………………….…………………….…...…...….12 How often should I re-calibrate the FiT tester………………………………….…..12 2009-9-22 FiT333(333-09Y03828)
  • Page 3: Measuring Instrument

    1. LCD with tough panel 2. Power Key 3. Back Key 4. “OK” Button 5. UP Key 6. Right Key 7. Down Key 8. Left Key 9. Mouth piece 10. Inner tube 11. USB Jack(Connect computer) 12. Printer 2009-9-22 FiT333(333-09Y03828)
  • Page 4: What Is What

    7. USB Car adaptor (connect the unit machine directly charging in the car), 1pcs 8. PC Download cable,1pcs (Option accessory) 9. Wireless Launch module,1pcs 10. Leather sheath, 1pcs 11. Printer paper, 4pcs 12. Charger,1pcs 13. Rechargeable Batteries 1.2V AA Ni-H(2400mAh or above),4pcs (Option accessory) 2009-9-22 FiT333(333-09Y03828)
  • Page 5: Basic Scientific Principles

    To achieve the high accuracy, user should study this manual carefully. And any use of the FiT333 requires full understanding and strict observation of these instructions.
  • Page 6: Preparation

    Press the “Power Key” key 3 seconds to turn ON the tester, than enter into the main interface. Press the “Power Key” few seconds (above 3 seconds) to turn OFF the tester. When the machine on, user can use either normal keys or touch screen for key operation 2009-9-22 FiT333(333-09Y03828)
  • Page 7: Operation Instructions

    1.6 Remove and change a new mouthpiece after each test. Push the REJECT trigger to repel the mouth piece 1.7 Printer: The printer can be detached from the tester (Option: The detached printer can be connected to a wireless module and become a wireless printer) 2009-9-22 FiT333(333-09Y03828)
  • Page 8: Alcohol Menu

    3. Change a new inner tube and mouth piece Change a new inner tube and mouth piece If test time above 30 minutes, please change a new inner tube or allow the device to rest for 3 minutes. 2009-9-22 FiT333(333-09Y03828)
  • Page 9: System Setting

    Enter the calibration mode by input the supervisor password together with a hardware key. Only allowed to perform this function by FiT or FiT Authorized service center (The detailed calibration procedure will only provided to FiT authorized dealer or service centre.) 2.4 Test record:...
  • Page 10: Misc

    Caution: User should take care the password. User can only ask FiT service centre to reset the password if user forgot it. Service centre may charge for this service. 3.5 Power Managent: set the period of power auto off and backlight time 3.6 Touch Screens Calibrate: When the touch screen setting shift, it can be re-calibrated.
  • Page 11: Accessory

    Then use the wireless printer to printing the test result as following. Connect the car Wireless receiver Printer module Caution: Keep the wireless printer in warm area. (inside the car) 6. Software Update (only suitable for FiT service centre) 7. Accessory: Standard accessory Skin sheath(1pcs) 09Y03672...
  • Page 12: Specification

    10. How often should I re-calibrate the FiT tester? The FiT tester can remain accurate for 6 months of use. The more frequent the use, the more the unit will need to be calibrated. According to D/N31051, we recommend recalibration on a 6 monthly (or earlier) basis to ensure maximum accuracy.