Professional breath alcohol analyzer with fuel cell sensor
Hide thumbs Also See for FiT333:

Advertisement

Quick Links

Professional Breath Alcohol Analyzer
With Fuel Cell Sensor
FiT333
IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell
in human mouth, etc...) may affect the Blood Alcohol Concentration (BAC) level, so
the Readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this
unit.
DO NOT drink before you drive!
www.aap.com.hk

Advertisement

Table of Contents
loading

Summary of Contents for FiT FiT333

  • Page 1 Professional Breath Alcohol Analyzer With Fuel Cell Sensor FiT333 IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc…) may affect the Blood Alcohol Concentration (BAC) level, so the Readings are For Reference Only. Neither the reseller nor manufacturer accept any liability arising from the use of this unit.
  • Page 2: Table Of Contents

    Formal Test……………………………………………………………..……………..…. 6-9 Quick start……………………………………………………….…………….….……….. 9 System Setting…………………………………………………….…………………...…… 9-10 Test record…………………………………………………………………………………. 11 Sensor Test…………………………………………….…..……………………………… 11 PC download………………………………………….…..……………………………… 12-16 Change the wireless printer module as following..……………………………………… 17 Specification…………………………………………………………………...…………..18 Calibration…………………………………………….…………………….…...…...…..18 How often should I re-calibrate the FiT tester………………………………….…..18 FiT333:333-15Y07526 2015-11-12...
  • Page 3: Measuring Instrument

    1. TFT QVGA 3.5” display with touch panel 2. Power Key 3. Back Key 4. “OK” Button 5. UP Key 6. Right Key 7. Down Key 8. Left Key 9. Mouth piece 10. Inner tube 11. USB Jack(Connect computer) 12. Printer FiT333:333-15Y07526 2015-11-12...
  • Page 4: What Is What

    8. PC download cable , 1pc 9. Car adaptor (connect the unit machine directly charging in the car), 1pc 10. Rechargeable Batteries 1.2V AA Ni-H(2300mAh or above), 4pcs 11. Ni-battery Charger,1pc 12. CD for Download software,1pc 13.User manual 1pc FiT333:333-15Y07526 2015-11-12...
  • Page 5: Basic Scientific Principles

    To achieve the high accuracy, user should study this manual carefully. And any use of the FiT333 requires full understanding and strict observation of these instructions.
  • Page 6: Preparation

    2.Press and hold the “Power Key” for about 3 seconds to turn OFF the machine. 3.If no key input for 10 minutes, the machine will power off automatically to save the battery. 4. User can use either normal keys or touch screen for key operation FiT333:333-15Y07526 2015-11-12...
  • Page 7: Operation Instructions

    Active test: Under this test mode, the device have require for air pressure. Blow continuously through the blowing tube for approximately 6 seconds. Ready-blow blowing sampling test result Passive test: Press OK key for taking breath sample. Ready-blow sampling FiT333:333-15Y07526 2015-11-12...
  • Page 8 “blow time-out” “blow abort” 1.6 If the breath sample is taken not successfully. Then will show as following. User need to re-test again. “Save” 1.7 Press to input the relevant pictures below: FiT333:333-15Y07526 2015-11-12...
  • Page 9 3. Change a new inner tube and mouth piece If continually use the machine for more than 15 minutes or water vapor condenses inside the inner tube, please change a new inner tube (or allow the device to rest for 3 minutes.) FiT333:333-15Y07526 2015-11-12...
  • Page 10: Quick Start

    “System Information”, “Advanced Setting”. Caution: The calibration is already been done before shipping, user alters the setting parameters will override all calibration data. Only FiT authorized technician is allowed to modify the calibration data. ① Set Unit Set the unit to Permillage ( ‰...
  • Page 11 Alcohol Calibrate (Available for Service Center only) Enter the calibration mode by input the supervisor password. Only allowed to perform this function by FiT or FiT authorized service center (The detailed calibration procedure will only provided to FiT authorized dealer or service centre.)
  • Page 12: Test Record

    4.3. Delete: to delete the test record 4.4. Exit: return to previous menu. 4.5 Delete all record: need input user password. Records in FiT 333 Machine can only be deleted through "super password" similar to advanced setting password 5. Sensor Test: Press “Sensor Test”...
  • Page 13: Pc Download

    (Remark: have to run the download software after copy all the files into computer, otherwise, the download software cannot work normally; the optical disk packed with FiT333) Step 3: Use the PC download cable to connect the 8pin USB port of the FiT333 machine with the computer USB port.
  • Page 14 Step 6: Open the Removable disk in the computer, find and click “ FiT_TestRecord.exe” file , then will see the interface as picture below: Step 7: Click “File’ and select “Load” to upload the data to computer, see picture below: FiT333:333-15Y07526 2015-11-12...
  • Page 15 To input the User ‘000000’ and Password ‘000000’, as below picture: User and Password is ok, display as below picture: To click ‘confirm’ return to below picture: FiT333:333-15Y07526 2015-11-12...
  • Page 16 Step 8: Click “File’ and select “Load” again to upload the data to computer as picture below: FiT333:333-15Y07526 2015-11-12...
  • Page 17 Step 10: In the computer, can use the office software to process the uploaded test record data. Please copy the file under the FiT333 file list of the CD into the computer disk, and run “CD-ROM\ FiT_TestRecord.exe” or register manually to have a re-registration, otherwise, will indicate that the software is not normal.
  • Page 18: Change The Wireless Printer Module As Following

    Use the provided car adaptor and connect to car cigarette plug. Then use the wireless printer to printing the test result as following. Connect the car Wireless receiver Printer module Caution: Keep the wireless printer in warm area. (Inside the car) FiT333:333-15Y07526 2015-11-12...
  • Page 19: Specification

    11. How often should I re-calibrate the FiT tester? The FiT tester can remain accurate for 1 year of use. The more frequent the use, the more the unit will need to be calibrated. According to DIN31051, we recommend recalibration every 12 months (or earlier) basis to ensure maximum accuracy.