McLean Cooling Technology Genesis M13-0116-G1014 Instruction Manual

McLean Cooling Technology Genesis M13-0116-G1014 Instruction Manual

Mclean genesis air conditioners instruction manual
Table of Contents

Advertisement

Pentair Technical Products
2100 Ho man Way
Minneapolis MN 55303 USA
+1.763.323.8200
+1.763.576.3200
PentairTechnicalProducts.com
Rev. V
INSTRUCTION MANUAL
Genesis™
Air Conditioner
All Models
© 2012 Pentair Technical Products
Protecting Electronics.
Exceeding Expectations.™
P/N 10-1008-170
87976469

Advertisement

Table of Contents
loading

Summary of Contents for McLean Cooling Technology Genesis M13-0116-G1014

  • Page 1 INSTRUCTION MANUAL Genesis™ Air Conditioner All Models Protecting Electronics. Exceeding Expectations.™ Pentair Technical Products 2100 Ho man Way Minneapolis MN 55303 USA +1.763.323.8200 +1.763.576.3200 PentairTechnicalProducts.com Rev. V © 2012 Pentair Technical Products P/N 10-1008-170 87976469...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER ......................................3 HANDLING AND TESTING THE AIR CONDITIONER .................................3 INSTALLATION INSTRUCTIONS ......................................4 M13 Design Data ..........................................5 M13 Dimensional Drawing ......................................5 M13 Mounting Gasket and Cutout Dimensions ..............................5 M13 Components List ........................................6 M13 Schematic and Wire Diagram, 115/230 Volt 1000 BTU ..........................7 M17 Design Data ..........................................8 M17 Dimensional Drawing ......................................8 M17 Mounting Gasket and Cutout Dimensions ..............................8...
  • Page 3: Receiving The Air Conditioner

    Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to McLean Cooling Technology -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Inspect air conditioner. Verify functionality before mounting the air conditioner, seeHANDLING AND TESTING THE AIR CONDITIONER on page 3. 2. Using the cutout dimensions shown in this manual or the cutout template printed on the units shipping carton, prepare the air “IN” and air “OUT” openings, and mounting bolt hole pattern for the enclosure.
  • Page 5: M13 Design Data

    M13 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M13-0116-G1014 Stock 50/60 4.0/4.0 800/1000 125/52 48/22 M13-0116-G1XXX 50/60 4.0/4.0 800/1000 125/52 48/22 M13-0126-G1008 Stock 50/60 2.2/2.1 800/1000 125/52 48/22 M13-0126-G1XXX...
  • Page 6: M13 Components List

    M13 Components List Part Number Item Part Description Number. 115 Volt 230 Volt Fan, Condenser 12-1012-01 12-1012-02 Fan, Evaporator 13-1015-01 13-1015-02 Coil, Condenser 13-1001-05 13-1001-05 Coil, Evaporator 13-1001-04 13-1001-04 Compressor, AE 10-1016-61 10-1026-71 Control Panel Assembly, Narrow 10-1106-100 10-1106-100 Filter, Air, Reusable, Narrow 10-1000-57 10-1000-57 Filter/Dryer...
  • Page 7: M13 Schematic And Wire Diagram, 115/230 Volt 1000 Btu

    M13 Schematic and Wire Diagram, 115/230 Volt 1000 BTU SERVICE CORD TO TEMPERATURE DISPLAY FUSE(S) (OPTIONAL) ELECTROMAGNETIC INTERFERENCE FILTER (OPTIONAL) TEMPERATURE DISPLAY (OPTIONAL) SUPPRESSOR (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR BLOWER COMPRESSOR SUPPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) THERMOSTAT COMPRESSOR CONDENSER BLOWER WITH OPTIONAL HEAD PRESSURE...
  • Page 8: M17 Design Data

    M17 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M17-0216-G009 Stock 110/115 50/60 6.6/6.7 1500/1800 125/52 56/25 M17-0216-GXXX 110/115 50/60 6.6/6.7 1500/1800 125/52 56/25 M17-0226-G004 Stock 220/230 50/60 4.2/3.7 1500/1800...
  • Page 9: M17 Components List

    M17 Components List Part Number Item Part Description Number. 115 Volt 230 Volt Fan, Condenser 12-1012-01 12-1012-02 Fan, Evaporator 12-1012-01 12-1012-02 Capacitor, Compressor, Start 10-1032-09 Coil, Condenser 17-1001-00 17-1001-00 Coil, Evaporator 17-1002-01 17-1002-01 Compressor, AE 10-1016-22 10-1026-74 Control Panel Assembly, Narrow 10-1106-100 10-1106-100 Filter, Air, Reusable, Narrow...
  • Page 10: M17 Schematic And Wire Diagram, 115 Volt 1800 Btu

    M17 Schematic and Wire Diagram, 115 Volt 1800 BTU SERVICE CORD FUSE(S) TO TEMPERATURE DISPLAY (OPTIONAL) ELECTROMAGNETIC INTERFERENCE FILTER (OPTIONAL) TEMPERATURE DISPLAY SUPPRESSOR (OPTIONAL) (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR BLOWER COMPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) SUPPRESSOR FREEZE THERMOSTAT (OPTIONAL) CONDENSER BLOWER COMPRESSOR THERMOSTAT...
  • Page 11: M28 Design Data

    M28 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M28-0216-G013 STOCK 50/60 9.8/9.0 2200/2200 125/52 98/45 M28-0216-GXXX 50/60 9.8/9.0 2200/2200 125/52 98/45 M28-0226-G004 STOCK 50/60 5.0/4.5 2200/2200 125/52 98/45 M28-0226-GXXX...
  • Page 12: M28 Mounting Gasket And Cutout Dimensions

    M28 Mounting Gasket and Cutout Dimensions (3.) Mounting gasket kit 28-1000-50 included. Apply gasket 1. Dashed lines represent air conditioner. to the back of the air conditioner before mounting to 2. Cutout dimensions are for standard unit. enclosure. 3. Hole may be deleted if service cord is routed through 3.00 x 13.50 cutout (except on units with electric heat).
  • Page 13: M28 Components List

    M28 Components List Part Number (115 Volt) Item Part Description Number. 2200 BTU 4000 BTU 6000 BTU Blower, Condenser 30-4019-01M 30-4019-01M 38-2019-04 Blower, Evaporator 28-1064-06M 28-1064-06M 28-1064-06M Capacitor, Compressor, Start/Run 10-1032-13 10-1032-15 Coil, Condenser 24-1001-00 24-1001-00 24-1001-00 Coil, Evaporator 28-1001-00 28-1001-01 14-1002-00 Compressor, AE/AK/AK...
  • Page 14: M28 Schematic And Wire Diagram, 115 Volt, 2200 Btu And 230 Volt 6000 Btu

    M28 Schematic and Wire Diagram, 115 Volt, 2200 BTU And 230 Volt 6000 BTU SERVICE CORD TO TEMPERATURE DISPLAY FUSE(S) (OPTIONAL) ELECTROMAGNETIC INTERFERENCE FILTER (OPTIONAL) TEMPERATURE DISPLAY (OPTIONAL) SUPPRESSOR (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR BLOWER COMPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) COMPRESSOR SUPPRESSOR CONDENSER BLOWER...
  • Page 15: M28 Schematic And Wire Diagram, 115/230 Volt, 4000 Btu & 230 Volt 6000 Btu

    M28 Schematic and Wire Diagram, 115/230 Volt, 4000 BTU & 230 Volt 6000 BTU FUSE(S) TO TEMPERATURE DISPLAY (OPTIONAL) SERVICE CORD ELECTROMAGNETIC INTERFERENCE FILTER (OPTIONAL) TEMPERATURE SUPPRESSOR RELAY DISPLAY (OPTIONAL) (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR START BLOWER CAPACITOR COMPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) CONDENSER BLOWER WITH OPTIONAL HEAD...
  • Page 16: M33 Design Data

    M33 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M33-0416-G010 Stock 50/60 13.0/13.2 3700/4000 125/52 105/48 M33-0416-GXXX 50/60 13.0/13.2 3700/4000 125/52 105/48 M33-0426-G009 Stock 50/60 7.2/7.3 3700/4000 125/52 105/48 M33-0426-GXXX...
  • Page 17: M33 Mounting Gasket And Cutout Dimensions

    M33 Mounting Gasket and Cutout Dimensions Mounting gasket kit 33-1000-50 included. Apply gasket 1. Dashed lines represent aire conditioner. to the back of the air conditioner before mounting to 2. Cutout dimensions for standard unit. enclosure. 3. Service cord to be routed through 2.00 x 11.12 cutout. 4.
  • Page 18: M33 Components List

    M33 Components List Part Number (4000 BTU) Item Part Description Number 115 Volt 230 Volt Blower, Condenser, Top Discharge 38-2019-04 38-2020-04 Blower, Condenser, Front Discharge 38-2019-00 38-2020-00 Fan, Evaporator 12-1012-01 12-1012-02 Capacitor, Compressor, Start 10-1032-13 10-1032-14 Coil, Condenser 33-2001-01 33-2001-01 Coil, Evaporator 33-2002-02 33-2002-02...
  • Page 19: M36 Design Data

    M36 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M36-0616-G307 Stock 50/60 10.0/10.0 5000/6000 105/48 M36-0616-GXXX 50/60 10.0/10.0 5000/6000 105/48 M36-0626-G306 Stock 50/60 5.0/5.0 5000/6000 105/48 M36-0626-GXXX 50/60 5.0/5.0 5000/6000...
  • Page 20: M36 Mounting Gasket And Cutout Dimensions

    M36 Mounting Gasket and Cutout Dimensions Mounting gasket kit 36-1000-50 included. Apply gasket 1. Dashed lines represent aire conditioner. to the back of the air conditioner before mounting to 2. Cutout dimensions for standard unit. enclosure. 3. Service cord to be routed through 3.00 x 14.00 cutout. - 20 - ©...
  • Page 21: M36 Components List

    M36 Components List Part Number (6000 BTU) Item Part Description Number 115 Volt 230 Volt Blower, Condenser 38-2019-04 38-2020-04 Blower, Evaporator 28-1064-06M 28-1064-05M Capacitor, Compressor, Run 52-6032-06 S-6173 Coil, Condenser 36-1017-01 36-1017-01 Coil, Evaporator 28-1001-01 28-1001-01 Compressor, Rotary 10-1016-91 10-1026-123 Control Panel Assembly, Wide 10-1106-101 10-1106-101...
  • Page 22: M52 Design Data

    M52 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) M28-0626-GXXX 50/60 13.0/13.0 5000/6000 125/52 155/70 M52-0626-XXX 50/60 6.5/6.5 5000/6000 125/52 155/70 M52-0816-032 Stock 50/60 14.5/14.5 6700/8000 125/52 160/73 M52-0816-XXX 50/60...
  • Page 23: M52 Mounting Gasket And Cutout Dimensions

    M52 Mounting Gasket and Cutout Dimensions Mounting gasket kit 52-1000-50 included. Apply gasket 1. Dashed lines represent air conditioner. to the back of the air conditioner before mounting to 2. Cutout dimensions for standard unit. enclosure. 3. Hole may be deleted if service cord is routed through 4.50 x 15.63 cutout (except on units with electric heat).
  • Page 24: M52 Components List

    M52 Components List Part Number (115 Volt) Item Part Description Number 6000 BTU 8000 BTU 10000 BTU 12000 BTU Blower, Condenser 52-6034-10 52-6034-10 52-6034-10 52-6034-10 Blower, Evaporator 52-6075-00 52-6075-00 52-6075-00 52-6034-10 Capacitor, Compressor, Run 52-6031-01 52-6032-01 52-6032-01 52-6032-01 Coil, Condenser 52-6111-00 52-6111-00 52-6111-00...
  • Page 25: M52 Schematic And Wire Diagram, 115 Volt 10000 And 12000 Btu

    M52 Schematic and Wire Diagram, 115 Volt 10000 and 12000 BTU FUSE(S) TO TEMPERATURE DISPLAY (OPTIONAL) SERVICE CORD ELECTROMAGNETIC INTERFERENCE FILTER (OPTIONAL) SUPPRESSOR TEMPERATURE DISPLAY (OPTIONAL) (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY CAPACITOR EVAPORATOR BLOWER CONTACTOR COMPRESSOR HEATER (OPTIONAL) SUPPRESSOR CONDENSER BLOWER WITH OPTIONAL HEAD PRESSURE CONTROL THERMOSTAT AND...
  • Page 26: Mhb11 Design Data

    MHB11 Design Data BTU/Hr. @ Max Ambient Shipping Full Load Model Availability Voltage Phase Max Ambient Temperature Weight Amps Temperature (°F/°C) (lb./kg) MHB11-0216-G306 STOCK 50/60 9.7/9.0 2200/2200 125/52 90/41 MHB11-0216-G3XX 50/60 9.7/9.0 2200/2200 125/52 90/41 MHB11-0226-G306 STOCK 50/60 5.5/4.6 2200/2200 125/52 90/41 MHB11-0226-G3XX...
  • Page 27: Mhb11 Mounting Gasket And Cutout Dimensions

    MHB11 Mounting Gasket and Cutout Dimensions Mounting gasket kit 11-1000-50 included. Apply gasket 1. Dashed lines represent air conditioner. to the bottom of the air conditioner before mounting to 2. Cutout dimensions are for standard unit. enclosure. MHB11 Components List Part Number (115 Volt) Part Number (230 Volt) Item...
  • Page 28: Mhb11 Schematic And Wire Diagram, 115 Volt, 2200 Btu And 230 Volt 6000 Btu

    MHB11 Schematic and Wire Diagram, 115 Volt, 2200 BTU And 230 Volt 6000 BTU TO TEMPERATURE DISPLAY FUSE(S) (OPTIONAL) ELECTROMAGNETIC INTERFERENCE TEMPERATURE DISPLAY (OPTIONAL) FILTER (OPTIONAL) SUPPRESSOR (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR BLOWER SUPPRESSOR COMPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) THERMOSTAT CONDENSER BLOWER WITH OPTIONAL HEAD...
  • Page 29: Mhb11 Schematic And Wire Diagram, 230 Volt, 2200 Btu

    MHB11 Schematic and Wire Diagram, 230 Volt, 2200 BTU TO TEMPERATURE DISPLAY FUSE(S) (OPTIONAL) ELECTROMAGNETIC INTERFERENCE TEMPERATURE DISPLAY (OPTIONAL) FILTER (OPTIONAL) SUPPRESSOR (OPTIONAL) TRANSFORMER WITH TEMPERATURE DISPLAY EVAPORATOR BLOWER START CAPACITOR SUPPRESSOR COMPRESSOR HEATER (OPTIONAL) THERMOSTAT (OPTIONAL) CONDENSER BLOWER THERMOSTAT WITH OPTIONAL HEAD PRESSURE CONTROL START CAPACITOR...
  • Page 30: Temperature Control

    TEMPERATURE CONTROL The electromechanical thermostat is factory preset to 75°F/23°C. To change the temperature setting, remove the front cover and screen. Use a standard screwdriver to adjust thermostat. For cooler temperatures turn clockwise, for warmer temperatures turn counterclockwise. PRINCIPLES OF OPERATION If electrical power to the air conditioner is interrupted and reapplied immediately, (within 3 to 5 seconds), the compressor may not restart due to the high back pressure of the compressor.
  • Page 31: How To Remove, Clean Or Install A New Inlet Air Filter

    How To Remove, Clean or Install a New Inlet Air Filter RP aluminum washable air filters are designed to provide excellent filtering efficiency with a high dust holding capacity and a minimum amount of resistance to air flow. Because they are constructed entirely of aluminum they are lightweight and easy to service.
  • Page 32: Trouble Shooting

    TROUBLE SHOOTING Basic Air Conditioning Trouble Shooting Check List 1. Check manufacturer’s nameplate located on the unit for correct power supply. 2. Turn on power to the unit. The evaporator (Enclosure or “COLD” air) blower should come on. Is there airflow? YES, proceed to step 3.
  • Page 33: Symptoms And Possible Causes

    Symptoms and Possible Causes: SYMPTOM POSSIBLE CAUSE Impellers/blowers not running Compressor not running Unit won’t cool Compressor runs, but has bad valves Loss of refrigerant Low line voltage at start. Should be +/-10% rated voltage. Compressor motor stuck Compressor tries to start but won’t run Bad contactor Bad overload switch Bad run/start capacitor...
  • Page 34: Warranty

    WARRANTY Pentair Technical Products warrants that the Goods manufactured by Pentair Technical Products will be free from defects in material and workmanship for a period of one (1) year from the date of shipment by Pentair Technical Products, subject to the following conditions and exclusions: C.
  • Page 35: Limitation Of Liability

    1. Complete Model Number, Serial Number and description of damaged unit being returned. 2. Original Buyer Purchase Order number and date product was received by Buyer. 3. Quantity to be returned and a brief description of failure for each unit, if different. 4.
  • Page 36 Protecting Electronics. Exceeding Expectations.™ Pentair Technical Products 2100 Ho man Way Minneapolis MN 55303 USA +1.763.323.8200 +1.763.576.3200 PentairTechnicalProducts.com Rev. V © 2012 Pentair Technical Products P/N 10-1008-170 87976469...

This manual is also suitable for:

Genesis m13-0116-g1xxxGenesis m130126g1008Genesis m13-0126-g1xxxGenesis m170216g009Genesis m17-0216-gxxxGenesis m170226g004 ... Show all

Table of Contents