Technical Data

Technical data
For domestic hot water heating applications which
utilize hot water heating boilers
Storage capacity
*1
Recovery rates
194°F
with a temperature rise
90°C
of the domestic hot
of the domestic hot
water from
water from
176°F
50 to 140°F /
80 ºC
10 to 60°C
and heating water supply
and heating water supply
temperature of
. . . . . .
158°F
at the supply flow rate
70 ºC
stated below
Supply flow rate
for the recovery
rates stated
Recovery rates
with a temperature rise
of the domestic hot
psig
water from
50 to 113°F /
50 to 113°F /
10 to 45°C,
15
a steam pressure of
psig
. . . . . .
and a max. steam velocity of
164 ft/s, 50 m/s
*2
Standby losses
Overall dimensions
Overall depth
Overall width
Width without enclosure
Overall height
Weight
Tank with insulation
Heating water content
(heat exchanger pipe coil)
Heat exchanger surface area
Connections
Heating water supply/return
Domestic cold/hot water
Domestic cold/hot water
Temp. and press. relief valve
Temp. and press. relief valve
*1
When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump.
The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under "Recovery
rates". Please also refer to the corresponding sizing chart at the end of this manual.
*2
Measured values are based on a room temperature of 68 ºF / 20 ºC and a domestic hot water temperature of 149 ºF / 65 ºC and can
vary by ±5%.
*3
To overcome mechanical room access problems, the front panel with thermometer and side panels can be removed, the adjustable feet
unscrewed, and the Vitocell 300-H turned on its side.
*4
This is the net width of the Vitocell 300-H after removing the outer casing to ease problems of access into the mechanical room.
4
USG
ltr
160
MBH
GPM
ltr/h
482
MBH
GPM
ltr/h
396
MBH
GPM
ltr/h
258
GPM
13.2
3
m
/h
MBH
GPM
ltr/h
MBH
GPM
ltr/h
MBH/24 h
inches
42¼
mm
1072
inches
25¼
mm
640
inches
mm
inches
25¾
mm
654
lbs
168
kg
USG
ltr
2
ft
9.36
2
m
0.87
∅'' (male thread)
∅'' (male thread)
∅'' (male thread)
∅'' (male thread)
∅'' (male thread)
Suitable for heating systems with:
H max. working pressure on heat exchanger side up to
220 psig at 392°F / 200°C or a steam pressure of 15 psig at 250°F / 121°C
H max. working pressure on DHW water side of up to 150 psig at 210°F / 99°C
42
53
200
96
113
2.1
2.5
568
78
85
1.8
1.9
430
51
58
1.1
1.3
292
22.0
3.0
5.0
Please see Vitocell-H 300 Steam Chart on page 16
Please see Vitocell-H 300 Steam Chart on page 16
4.4
5.1
48¾
1236
25¼
640
––
––
25¾
654
185
76
84
1.8
2.1
7
8
9.7
0.9
1
1
¾
¾
¾
¾
¾
¾
1
1
92
119
350
450
239
280
5.3
6.2
1204
1410
174
212
3.9
4.7
877
1066
116
133
2.6
3.0
585
671
22.0
22.0
5.0
5.0
6.5
8.2
62½
65
1590
1654
32¾
35¾
830
910
*3
*4
30¼
32
*3
*4
768
810
31
35
786
886
379
421
172
191
3.4
4.2
13
16
18.3
22.6
1.7
2.1
1
1
VITOCELL 300-H

Advertisement

loading