Connecting Sensors to the HVR

Each HVR unit may have up to 16 Sensor inputs. These inputs can be used with devices such as
infrared devices, motion device, glass breakage alarms, door and window trips, and many more. The
Sensors can be set to Normally Open or Normally Closed inside the software.
There are 4 Common Grounds (-) and 16 sensor inputs (+). There is no power supplied to the ports so
an external power supply must be used if power is necessary.

8/16 Channel

Common Ground

Connecting Control Outputs to the HVR

Each HVR unit may have up to 4 Control Outputs. These outputs can be used to trigger devices such
as Sirens, Phone Dialers, Lights, and any other relay activated device. There is no power supplied to
the ports. Use an external power supply if necessary.
8/16 Channel
Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
Maximum voltage is 24V AC @ 1 amp
Output uses a Form C Relay
30720AB
Sensor Inputs
(-)
External Power Supply (DC 12V)
Siren, Alarm, Outside Relays
(+)