Connecting Sensors To The Hvr; Connecting Control Outputs To The Hvr - OpenEye OE5-X3U24016 Hardware Manual

Hybrid video recorder h-series; x-series; h4 series; x4 series; x3 series
Hide thumbs Also See for OE5-X3U24016:
Table of Contents

Advertisement

Connecting Sensors to the HVR

Each HVR has up to 16 Sensor inputs. These inputs can be used with devices such as infrared devices,
motion device, glass breakage alarms, door and window trips, and many more. The Sensors can be set
to Normally Open or Normally Closed inside the software.
There are 4 Common Grounds (-) and 16 sensor inputs (+). There is no power supplied to the ports so
an external power supply must be used if power is necessary.
Common Ground

Connecting Control Outputs to the HVR

Each HVR has up to 16 Control Outputs. These outputs can be used to trigger devices such as Sirens,
Phone Dialers, Lights, and any other relay activated device. There is no power supplied to the ports.
Use an external power supply if necessary.
(-)
External Power Supply (DC 12V)
Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
Maximum voltage is 24V AC @ 1 amp
Output uses a Form C Relay
30720AB
COM
Sensor Inputs
COM
(+)
Siren, Alarm, Outside Relays
25

Advertisement

Table of Contents
loading

Table of Contents