Numeric Error Codes; Error Messages - Lenovo B430 Hardware Maintenance Manual

Hide thumbs Also See for B430:
Table of Contents

Advertisement

Numeric error codes

Table 2. Numeric error codes
Symptom or error (beeps, if any)
0187
EAIA data access error - The access to EEPROM is failed.
(two short beeps)
0189
Invalid RFID configuration information area - The EEPROM
checksum is not correct.
(two short beeps)
0190
Critical low-battery error
(two short beeps)
0191
System Security - Invalid Remote Change requested.
0251
System CMOS checksum bad - Default configuration
used.
(two short beeps)
0271
Date and time error - Neither the date nor the time is set
in the computer.
(two short beeps)
1802
Unauthorized network card is plugged in - Turn off and
remove the miniPCI network card.
(two short beeps)

Error messages

Table 3. Error messages
Symptom or error (beeps, if any)
Fan error.
(four short beeps, one long beep)
This system does not support batteries that are not
genuine Lenovo-made or authorized. The system will
continue to boot, but may not charge unauthorized
batteries.
Attention: Lenovo has no responsibility for the
performance or safety of unauthorized batteries, and
provides no warranties for failures or damage arising out
of their use.
FRU or action, in sequence
System board.
System board.
1. Charge the battery pack.
2. Battery pack.
1. Run the Lenovo Setup program, and then save
current setting by pressing Fn+F10.
2. System board.
1. Charge the backup battery for more than 8 hours
by connecting the ac power adapter.
2. Replace the backup battery and run the Lenovo
Setup program to reset the time and date.
Run the Lenovo Setup program to reset the time and
date.
1. Remove the Mini PCI network card.
2. System board.
FRU or action, in sequence
1. Fan.
2. Thermal grease.
3. System board.
Replace the battery.