Electrical Adjustments
Group/
Item Name
Item
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset
(Temp)
Temp B Warning Offset
16
(Temp)
17 Temp C Warning Offset
(Temp)
18 Temp B-A Warning Offset
(Temp)
Temp C-A Warning Offset
19
(Temp)
Temp A Warning Offset
0
(Time)
1 Temp B Warning Offset
(Time)
 Temp C Warning Offset
(Time)
Temp B-A Warning Offset
3
(Time)
4 Temp C-A Warning Offset
(Time)
Group
Fan control range Setting (temp./Voltage)
254
10 Normal Fan Control Min Temp
Normal Fan Control Max
11
Temp
1 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan Min
15 Normal Fan Max
16 Normal Fan3 Min
17 Normal Fan3 Max
0 Eco Fan Control Min Temp
1 Eco Fan Control Max Temp
 Eco Fan1 Min
3 Eco Fan1 Max
4 Eco Fan Min
5 Eco Fan Max
6 Eco Fan3 Min
7 Eco Fan3 Max
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
1 Fan Initial Volt
 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan Cooling Speed
6 Fan3 Cooling Spees
8 Cooling Time L1
9 Cooling Time L
10 Temp Error Cooling Time
OnStart Cooling Start Thresh-
11
old
1 After shutdown cooling
Group
Fan lamp Voltage down Setting
256
0 Lamp Voltage
Function
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Initial
100
100
100
100
44
44
43
44
60
60
60
60
60
60
63
63
100
100
100
100
100
100
100
100
5
5
5
0
0
3
3
3
3
3
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
33
33
35
35
38
39
39
39
7
77
95
95
15
15
15
15
68
75
85
90
80
80
80
80
77
8
95
95
135
135
135
135
30
30
35
35
38
38
39
39
50
55
85
85
115
10
15
15
45
45
60
60
50
50
6
6
70
75
90
95
15
15
15
15
55
55
55
130
130
130

3
3
38
1
-
-45-
range
Note
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
1-15
1-15
1-15
0-100
0-1
0-55