Check procedure Mode
q
Playback power output "ppw"
w
Recording power output "rpw"
"rpw" not achieved.
*1: Poor soldering of the line at Pin 100 of IC1401.
Check the line of Pin 93 of IC1401 for short and poor soldering. (Check all the way to the SW P.C.B.)
*2: Check the line of Pin 3 of IC1401 for poor soldering and short with other patterns.
Check the pick-up laser for breakage.
Confirmation of pick-up laser power
Recording and reproduction can be checked by using the laser power meter. However it should be
used for checking only because there is variation in its measurement.
When the measured value is excessively deviated from the reference value, replace the pick-up.
Reference value (measured at room temperature of 25 °C)
During reproduction (ppw) : 0.72 ± 0.1 mW
During recording : 5.5 ± 0.5 mW
Note : Be very careful when using the laser power meter. The laser beam would cause damage to
your eye if exposed to it directly.
TEMP (temperature standard) setting
(Make this setting quickly when the room temperature is within the range of 21 ˚C to 29 ˚C and
the P.C.B. is cold.)
(1) Set to the TEMP setting mode menu.
[ TEMP
]
: Temperature measured value
: Temperature setting value
(2) Make temperature correction based on the ambient temperature and according to the following
table.
Example : When the temperature measured value is 7A
7A
(measured value) - 01
H
H
* If the temperature measured value deflects between two values, use the smaller value (If 7A
above example, use 79
.)
H
(3) Using the jog dial, match the value obtained in Step (2) with the temperature setting value.
Example : When the temperature measured value is 7A
[ TEMP 7A 79 ]
Temperature setting value
Check item
(Pin 3 of IC1401)
DC 0.2V
DC 1.5V
DC 1.8V
Less than DC1.5V NG
Ambient temperature
+ 21.0 ˚C ~ + 23.2 ˚C
+ 23.3 ˚C ~ + 26.8 ˚C
+ 26.9 ˚C ~ + 30.7 ˚C
and the ambient temperature is 22 ˚C:
H
(correction value) = 79
(setting value)
H
and the ambient temperature is 22 ˚C:
H
Judgement
Possible cause and check content
OK (Move on to check w.)
NG
Perform *1.
OK (End of checking.)
Perform *2.
NG
Perform *1.
Correction value
– 1
H
± 0
H
+ 1
H
and 79
H
H