Description of TEST modes
1. EJECT mode
[ _ _ EJECT _ _ _ ]
2. AUTO preliminary adjustment mode
[ _ AUT _ YOBI _ ]
3. AUTO adjustment mode
[ AUTO _ AJST _ ]
4. AUTO AFB adjustment mode
[ _ AUT _ AFB _ _ ]
RESULT preparation mode
[ _ RST _ YOBI _ ]
RESULT mode (main adjustment)
[ _ RESULT _ _ _ ]
MANUAL preliminary adjustment mode
[ _ MNU _ YOBI _ ]
MANUAL adjustment mode
[ _ MNU _ AJST _ ]
5. EEPROM setting mode
[ EEPROM _ SET ]
6. TEST-PLAY mode
[ TEST _ PLAY _ ]
7. TEST-REC mode
[ TEST _ REC _ _ ]
8. INNER mode
[ _ _ INNER _ _ _ ]
1. EJECT mode
Step
Setting method
1
EJECT status in the TEST mode
2
Press the INPUT button.
3
Press the INPUT button.
4
Press the INPUT button.
5
Press the TITLE edit button.
6
Press the CHARA. button.
7
Press the DISPLAY button.
8
Press the DELETE/CANCEL button.
9
To TEMP setting (of EEPROM setting)
To CONTROL setting (of EEPROM setting)
Laser power setting (record/reproduction power) is performed.
Automatic preliminary adjustment is performed.
Adjusted values are output by using the interface.
Automatic adjustment is performed. (Grating adjustment mode after this adjustment.)
Adjusted values are output by using the interface.
Continuous reproduction is performed. (Error rate on display, jump test)
Automatic focus balance adjustment is performed.
Adjusted values are output by using the interface.
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Various factors of the digital servo function are changed manually.
The voltage is measured at the temperature detect terminal and the standard value is set.
Continuous reproduction from the specified address is performed.
C1 error rate is measured and ADIP error rate is measured.
Continuous recording from the specified address is performed.
The position where the INNER switch is turned ON is measured.
Remark
EJECT menu (No disc is loaded.)
Reproduction power output status
Recording power output status
Since this mode is not required for servicing , proceed to another mode promptly.
To TEMP setting
(Refer to TEMP setting)
To CONTROL1 setting
To CONTROL2 setting
EJECT menu
Display
[ _ _ EJECT _ _ _ ]
[ ppw _ _ _ _ _ _ _ ]
[ rpw _ _ _ _ _ _ _ ]
[ xpw _ _ _ _ _ _ _ ]
[ TEMP _
_
]
[ CONTROL1 _ 08 ]
[ CONTROL2 _ 02 ]
[ _ _ EJECT _ _ _ ]