INTRODUCTION DANGER - indicates a hazard which, if not avoided, will result in death or serious injury. Thank you for purchasing products by our company, we WARNING - indicates a hazard which, if not appreciate your business. The generator is a compact, avoided, could result in death or serious injury.
• DO NOT stop engine by moving choke control to WARNING - This generator does not meet U.S. Coast “OFF” position. Guard Regulation 33CFR-183 and should not be used in marine applications. Failure to use the appropriate U.S. WHEN TRANSPORTING, OR REPAIRING EQUIPMENT Coast Guard approved generator could result in death or serious injury and/or property damage.
• Keep at least 5 feet (1.5 m) of clearance on all sides • Open carton completely by cutting each corner of generator including overhead. from top to bottom. • Replacement parts must be the same and installed • Leave generator on carton to install wheel kit. in the same position as the original parts.
• Refer to Figures to install wheels as shown. 7 - BATTERY 16 - CARBON CANISTER • Slide the axle through the frame brackets. 8 - 120/240 VOLT AC, 17 - FUEL TANK CAP • Slide on the wheel and flat washer, then assemble 30 Amp TWIST LOCK flange nuts.
SION. If fuel spills, wait until it evaporates before start- • Place generator on a flat, level surface. ing engine. Check fuel lines, tank, cap and fittings fre- • Clean area around oil fill and remove oil fill cap and quently for cracks or leaks.
WATTAGE REFERENCE GUIDE Tool or Appliance Running* Additional Start- Garage Door 2350 (Rated) ing (Surge) Watts Opener - 1/2 HP Watts Electric Water 4700 11700 Essentials Heater Light Bulb - 75 — Job Site watt Quartz Halogen 1000 — Furnace Fan 2350 Work Light Blower - 1/2 HP...
Page 9
then fully into ON position. Unplug all electrical loads from the unit’s receptacles NOTICE - If battery is discharged, use manual starting before starting the engine. Make sure the unit is in a instructions. level position. Turn the Fuel Shut-off level Valve to the “On” position. Move engine choke lever to the ON position.
DO NOT touch hot muffler and AVOID hot exhaust Add up the total wattage of all electrical devices to be gases. Allow equipment to cool before touching. Keep connected at one time. This total should NOT be greater at least 5 feet (152 cm) of clearance on all sides of gen- than the generator’s wattage capacity.
main emissions compliant, high altitude adjustment is Some adjustments will need to be made periodically to required. Operation without this adjustment will cause properly maintain the generator. decreased performance, increased fuel consumption, and increased emissions. See an authorized dealer for All adjustments in the Maintenance section of this high altitude adjustment information.
6.2.3 ENGINE MAINTENANCE • Stop the engine and pull the spark plug wire off of the spark plug. • Clean the area around the spark plug and DANGER - When working on the generator, always remove it from the cylinder head. disconnect spark plug wire from spark plug and keep • Set the spark plug’s gap to 0.70-0.80 mm (0.028- wire away from spark plug.
DANGER - Drain fuel into approved container out- doors, away from open flame. Be sure engine is cool. Do not smoke. DANGER - NEVER cover the generator while engine and exhaust area are warm. SECTION 7 - STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage.
• Replace the gasoline can if it has started to rust. • INSTALLATION AND MAINTENANCE: This warranty Rust and/or dirt in the gasoline will cause problems does not cover the generator or parts when they have with the carburetor and fuel system. been subjected to improper or unauthorized use, as- • If possible, store the unit indoors and cover it to sembly, altered, modified, or damage due to misuse,...
SECTION 9 - TROUBLESHOOTING Problem Cause Correction Engine is run- 1.One of the circuit breakers is off. 1.Turn circuit breaker to ON. ning but no AC 2.Fault in generator. 2.Contact Authorized Service facility. output is avail- 3.Poor connection or defective cord set. 3.Check and repair.