Slant/Fin EUTECTIC EC-13A Installation And Operating Instructions Manual page 16

Oil-fired water boilers/no. 2 oil
Hide thumbs Also See for EUTECTIC EC-13A:
Table of Contents

Advertisement

16
BURNER DATA - RIELLO BURNERS FOR PACKAGED BOILERS ONLY
(RIELLO R-40 SERIES W/SHORT TUBE)
Boiler
Burner
Blast
Model
Model
Tube
#271T1
EC-13
F-3
6" Tube
#271T1
EC-14
F-5
6" Tube
#271T1
EC-15
F-5
6" Tube
#271T1
EC-16
F-5
6" Tube
† Air shutter and head settings shown are approximate ONLY. See START-UP page 8. Seal joint between flange and air tube with a suitable high
temperature sealant.
NOTE: Insertion depth is 127mm (5").
It is suggested that due to the positive pressure observed in the chamber that the air tube hole and any other passages of the flue gas
leakages be sealed to avoid combustion gas fumes from leaking into the boiler room.
Figure 11A. Riello 40 Series. Model F-3 & F-5 Electrode Setting
Firing Rate
Size
L/hr
GPH
L/hr
0.65
2.46
2.08
0.7
2.65
2.08
0.8
3.02
2.46
0.9
3.40
2.84
1.00
3.78
3.21
1.1
4.16
3.21
1.15
4.35
3.21
1.25
4.73
3.78
Nozzles
Angle &
MFR.
GPH
Type
0.55
80*A
Delavan
0.55
80*A
Delavan
0.65
60*B
Delavan
0.75
60*B
Delavan
0.85
60*W
Delavan
0.85
60*W
Delavan
0.85
60*B
Delavan
1.00
60*B
Delavan
EUTECTIC EC-10
Oil Pump
Approx.
Head
kPa
(PSIG)
Setting †
140
1
965
162
1
1117
150
0
1034
145
1
1000
138
1
952
168
1
1158
185
2
1276
155
2
1069
Approx.
Air
Setting †
3.75
4.1
2.3
2.5
2.6
3
2.8
3.2

Advertisement

Table of Contents
loading

Table of Contents