Sony CDX-M60UI Service Manual page 29

Fm/am compact disc player; fm/mw/lw compact disc player
Hide thumbs Also See for CDX-M60UI:
Table of Contents

Advertisement

• IC Pin Function Description
MAIN BOARD (3/3) IC501 MB90F883AHPF-GE1 (SYSTEM CONTROL)
Pin No.
Pin Name
1
CYRIL_SEL
2
B-OUT_SEL
3
COL_SW
4
ILLUMI_SEL
5
DOOR_SW
6
DOOR_IND
7
NOSE_SW
8 to 10
NCO
11
RE_IN0
12
RE_IN1
13
X_OUT
14
X_IN
15
VCC
16
VSS
17
C
18
UNISI
19
UNISO
20
UNISCK
21
NCO
22
I2C_SIO
23
I2C_SCK
24
NCO
25
ACC_IN
26
TEL_ATT
27
ATT
28
BUS_ON
29
SYS_RST
30
CD_ON
31
CDM_ON
32
AVCC
33
AVRH
34
RC_IN1
35
AVSS
36
NCO
37
VSM
38
SA_IN
39
KEY_IN1
40
KEY_IN0
41
RC_IN0
42, 43
NCO
44
VSS
45
KEY_ACK0
46
KEY_ACK1
47
NCO
48
LCD_CE
49
LCD_SO
50
LCD_SCK
51
MOD2
52
MOD1
53
MOD0
54
RESET
55
AREA_SEL2
56
AREA_SEL1
57
AREA_SEL0
I/O
I
Cyril select signal input (L: No cyril select)
I
Black out setting signal input (L: No black out)
I
Key illumination initial color setting signal input (H: Blue)
I
Key illumination voltage setting signal input (L: 9 V)
I
Front panel open detect signal input
O
Door indicator control signal output
I
Front panel detach detect signal input
O
Not used. (Open)
I
Rotary encoder signal input 0
I
Rotary encoder signal input 1
O
Low speed operation clock signal output (32.768 kHz)
I
Low speed operation clock signal input (32.768 kHz)
Power supply pin (+3.3 V)
Ground
Regulator reference capacitor connecting pin
I
SONY-BUS data input
O
SONY-BUS data output
O
SONY-BUS clock signal output
O
Not used. (Open)
I/O
I2C serial data input/output
O
I2C serial clock signal output
O
Not used. (Open)
I
Accessory power supply detect signal input
I
Telephone attenuator detect signal input
O
Audio mute control signal output
O
BUS ON signal output
O
System reset signal output
I
CD mechanism servo power supply control request signal input
I
CD mechanism deck power supply control request signal input
A/D converter power supply pin (+3.3 V)
A/D converter external reference power supply pin (+3.3 V)
I
Rotary commander shift key signal input 1
Ground for A/D converter
O
Not used. (Open)
I
S meter voltage detect signal input
I
Spectrum analyzer DC input
I
Key signal input 1
I
Key signal input 0
I
Rotary commander shift key signal input 0
O
Not used. (Open)
Ground
I
Key acknowledge detect signal input (Rotary commander)
I
Key acknowledge detect signal input (Front panel)
O
Not used. (Open)
O
LCD driver chip enable signal output
O
LCD driver serial data output
O
LCD driver serial clock signal output
I
Micon operation mode setting signal input (active: L)
I
Micon operation mode setting signal input
I
Micon operation mode setting signal input (active: H)
I
Reset signal input
I
Destination setting pin 2 (L: CDX-M60UI/MR60UI, H: CDX-M60UI)
I
Destination setting pin 1 (Fixed at L)
I
Destination setting pin 0 (L: CDX-M60UI, H: CDX-MR60UI)
CDX-M60UI/MR60UI
Description
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdx-mr60ui

Table of Contents