10-7. Useful Functions
10-7-1. Self-Diagnosis by LED Indication
For this outdoor unit, by referring to the 5 LED (Red) indicator lights, self-diagnosis is possible.
LEDS (Red, D09 to D13) are located on the sub-control board underneath the inverter.
Contents
Normal running
IGBT short circuit, Compressor motor rear short
Trouble on position detecting circuit
Trouble on current detecting circuit
Condensor pipe temp. sensor (TE) fault
Suction pipe temp. sensor (TS) fault
Discharge pipe temp. sensor (TD) fault
Trouble on outdoor fan
Outdoor temp. sensor (TO) fault
Trouble on compressor system
Gas side pipe temp. sensor a (TGa) fault
Gas side pipe temp. sensor b (TGb) fault
TGa, TGb sensor out of place, P.M.V. fault
Communication trouble between M.C.U.
Compressor lock
Trouble on discharge temp. Gas leakage
Compressor break down
These LEDs do not normally light.
1. If trouble occurs, LED (Red) goes on according to the
contents of trouble as shown in the table above.
2. When two or more troubles occur, LEDs go on cyclically
(alternately).
3. When the trouble is eliminated, LEDs (Red) go off.
This product is compliant with Directive 2002/96/EC, and cannot be disposed as unsorted
municipal waste.
This product must be returned to the appropriate collection facility, as specifi ed by your
municipality.
Indoor alarm code
D09
None
14
16
17
18
18
19
1A
1B
1C
1C
1C
1C
1C
1D
1E
1F
D09 D10 D11 D12 D13
D09 D10 D11 D12 D13
LED (Red)
LED (Red)
– 71 –
LED indication
D10
D11
D12
: LED ON,
: LED OFF
Fig. 10-7-1
Fig. 10-7-1
D13

Hide quick links: