Facing / Mantel - Lennox VILLA VISTA 850028M Installation And Operation Instructions Manual

Wood burning fireplaces
Table of Contents

Advertisement

Facing
1. Combustible wall (such as drywall panels) must be installed flush with
the fireplace. It may not project in front of and on the fireplace (i.e.
the steel facade of the fireplace (see Figure 13).
2. Decorative frame made of combustible material cannot project in front
of and on the fireplace steel front, in the space delimited by the width
of the unit (38") and a height of 54" from the base of the appliance
(see Figure 15).
3. Non-combustible materials such as brick, stone or ceramic tile may
project in front of and onto the fireplace facing (see Figure 14).
*
54"
Figure 13
Figure 15
12
1/2" GYPSUMBOARD
2" x 3" MIN.
SPACER
MANTEL
54"
NOTE: DIAGRAMS & IllUSTRATIONS ARE NOT TO SCAlE.
Mantel
The mantel must be installed at least 54" (1372 mm) above the base of
the fireplace (see Figure 13).
*NOTE: Mantel can be reduced to 48" (1219 mm) if the Clean Face Panel
option is installed with the gravity kit.
NON
COMBUSTIBLE
FACING
Figure 14
38"
COMBUSTIBLE
CAN NOT
PROJECT OVER
OR IN FRONT
OF THE
FIREPLACE
1/2" GYPSUMBOARD
2" x 3" MIN.
SPACER

Advertisement

Table of Contents
loading

Table of Contents