4

Electrical Characteristics

4.1 Absolute Limiting Values

Any (also temporary) stress in excess of the
limiting values may cause permanent damage
on SBR-FX/RMD. Exposure to limiting condi-
tions for extended periods may affect the relia-
bility and shorten the life time of the device.
Parameter
Storage temperature
Operating
temperature
Supply voltage
Voltage on bus
connections
EMS Dr. Thomas Wünsche
User Manual
Min.
Max.
Unit
–25
+70
°C
0
+50
°C
–100
+35
V
–30
+30
V
11
User Manual

4.2 Nominal Values

Parameter
Current
consumption
Supply voltage
Optical damping
(SBR-FX15000)
Optical damping
(SBR-FX40000)
Admissible fiber
length
(SBR-FX15000)
Admissible fiber
length
(SBR-FX40000)
All values, unless otherwise specified, refer to
a supply voltage of 24V and an environmental
temperature of 20°C. Fiber length specifica-
tions are valid for a fiber damping of
0,55dB/km without additional patch panels.
12
EMS Dr. Thomas Wünsche
SBR-FX/RMD
Min
Typ
Max
Unit
80
200
mA
20
24
30
V
-
13
dB
4
28
dB
15
km
40
km