Introduction
You have just received an FLE-150 150kW Electric Construction Heater manufactured by Flagro Industries.
Use: The FLE-150 Electric Construction Heater is designed for temporary heat only.
The heater may be installed indoors or out and used to bring 100% outdoor air, or heat
and re-circulate building air. The FLE-150 is designed to heat large spaces, buildings
and machines without worrying about on site fuel.
Quality: The FLE-150 is built with the highest quality of components, giving our
customers the confidence they deserve in a Flagro product.
Convenience: The FLE-150 gives our customers the flexibilty of a 60kW/90kW/150kW heat setting.
The heater is equipped with a; fan speed inverter control that provides optimum temperature rise
by adjusting blower output at each heat setting. Colour coded Cam Lock power connections
for easy installation. Remote thermostat option available.
Safety
Always verify that you have proper voltage supply. (480V) It is important to check
the wiring connections inside the heater before plugging in the Cam Locks.
Use a meter to measure volt supply to each cam lock.
Work on the internal systems should only be attempted by a certified electrician and
only when power has been disconnected and can not be reconnected to the heater.
Grounding
The heater is supplier with a cam lock system with a grounding connection and is indicated with a "G"
on the cam lock panel. The heater is also supplied with a grounding nuts found on all panels.
It is very important to double check that all grounding connections are properly secure.
Clearance from Combustibles
The discharge temperature of these units may reach very high temperatures. Maintain minimum
distance from combustible materials as follows:
Top: 6 Inches
Bottom: 6 Inches
Sides: 6 Inches
Discharge: 15 FT

Hide quick links: