LG 32LM6200 Service Manual page 10

Hide thumbs Also See for 32LM6200:
Table of Contents

Advertisement

Adj. protocol
Protocol
Command
Enter adj. mode aa 00 00
Source change
xb 00 04
xb 00 06
Begin adj.
ad 00 10
Return adj. result
Read adj. data
(main)
ad 00 20
(sub )
ad 00 21
Confirm adj
ad 00 99
.
End adj.
aa 00 90
Ref.) ADC Adj. RS232C Protocol_Ver1.0
Adj. order
▪aa 00 00 [Enter ADC adj. mode]
▪xb 00 04 [Change input source to Component1(480i&1080p)]
▪ad 00 10 [Adjust 480i&1080p Comp1]
▪xb 00 06 [Change input source to RGB(1024*768)]
▪ad 00 10 [Adjust 1920*1080 RGB]
▪aa 00 90 End adj.
Ref) ADC adj. RS232C Protocol_Ver1.0
4.2 LAN Inspection
4.2.1 Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
4.2.2 LAN inspection solution
LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ setting automatic IP
▪ Setting state confirmation
If automatic setting is finished, you confirm IP and MAC Address.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Set ACK
a 00 OK00x
b 00 OK04x (Adjust 480i, 1080p Comp1 )
b 00 OK06x (Ad just 1920*1080 RGB)
OKx (Case of Success)
NGx (Case of Fail)
(main)
000000000000000000000000007c007b006dx
(Sub)
000000070000000000000000007c00830077x
NG 03 00x (Fail)
NG 03 01x (Fail)
NG 03 02x (Fail)
OK 03 03x (Success)
a 00 OK90x
4.2.3 WIDEVINE Key Inspection
. WIDEVINE Key Inspection
- Confirm Key input Data at the "IN START" MENU Mode
4.3 LAN PORT INSPECTION(PING TEST)
4.4.1. Equipment setting
1) Play the LAN Port Test PROGRAM.
2) Input IP set up for an inspection to Test
Program.
*IP Number : 12.12.2.2
4.4.2. LAN PORT inspection (PING TEST)
1) Play the LAN Port Test Program.
2) connect each other LAN Port Jack.
3) Play Test (F9) button and confirm OK Message.
4) remove LAN CABLE
- 10 -
LGE Internal Use Only

Hide quick links: