REED ST-118 Instruction Manual

3 in 1 pocket autoranging

Advertisement

Quick Links

Model
Pantone 534 Blue - 100/80/30/5
3 in 1 Pocket Autoranging
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/

Digital Multimeter

www
ST-118
reedinstruments
Black
Instruction
Manual
com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST-118 and is the answer not in the manual?

Questions and answers

Summary of Contents for REED ST-118

  • Page 1: Digital Multimeter

    Black ST-118 Model Pantone 534 Blue - 100/80/30/5 3 in 1 Pocket Autoranging Pantone 485 Red - 10/100/100/5 Pantone 123 Yellow - 0/27/100/ Digital Multimeter Instruction Manual reedinstruments...
  • Page 2: International Safety Symbols

    Features • 3-1/2 digit (2000 count) LCD display • Built-in non-contact AC voltage detector plus flashlight • Double Molded housing • CATIII 1000V • UL approved • 200mA/500V Resettable Fused current inputs and overload protection on all ranges • Autoranging with auto power off Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present. Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter. Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow 2. Make sure any covers or battery doors are properly closed and secured.
  • Page 3: Meter Description

    3. Always disconnect the test leads from any voltage source before replacing the battery or fuses. 4. Do not exceed the maximum rated input limits. Input LImIts Function maximum Input V DC or V AC 600V DC/AC 200mA/500V fast acting µA, mA AC/DC Resettable Fuse Resistance, Diode 600V DC/AC & Continuity Test 5. Take care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 6. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. 7. Remove the battery from the meter if the meter is to be stored for long periods. Meter Description 1 — Non-contact AC voltage detector probe tip 2 — Non-contact AC voltage indicator light 3 — 3 1/2 Digit (2000 count) 4 — MODE button 5 — Function switch 6 — Flashlight 7 — Flashlight button Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow...
  • Page 4: Specifications

    Specifications Function Range Accuracy DC Voltage 200mV, ±(0.5% rdg + 3d) 2.000V, 20.00V, 200.0V, 600V ±(1.2% rdg + 3d) AC Voltage 2.000V, 20.00V ±(1.0% rdg + 8d) 40-400Hz 200.0V, 600V ±(2.3% rdg + 10d) DC Current 200.0µA, 2000µA ±(2.0% rdg + 8d) 20.00mA, 200.0mA AC Current 200.0µA, 2000µA ±(2.5% rdg + 10d) 20.00mA, 200.0mA Resistance 200.0Ω ±(0.8% rdg + 5d) 2.000kΩ, 20.00kΩ, 200.0kΩ ±(1.2% rdg + 5d) 2.000MΩ ±(5.0% rdg + 5d) 20.00MΩ ±(10.0% rdg + 5d) MAX INPUT VOLTAGE 600V AC/DC DIODE TEST Test current 1mA max., open circuit voltage of 1.5V typical CONTINUITY CHECK Audible signal if the resistance is <150Ω...
  • Page 5: Operation

    Operation AC/DC VOltAge MeASureMentS CAutIOn: Do not measure AC/ DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green V position. 2. Press the MODE button to indicate “DC” or “AC” on the display. 3. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 4. Read the voltage in the display DC/AC Current MeASureMentS 1. Set the function switch to the µA/mA position. 2. For current measurements up to 2000µA DC/AC, set the function switch to the mA position 3. Press the MODE button to indicate “DC” / “AC” on the display. 4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current. 5. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 6. Apply power to the circuit. 7. Read the current in the display nOte: 0.2A/500V fast acting Resettable Fuse current inputs and Blue - 100/80/30/5 Pantone 534 Blue Overload protection on mA, µA ranges. No replacement required. Yellow - 0/27/100/0 Pantone 123 Yellow Red - 10/100/100/5 Pantone 485 Red Yellow - 0/27/100/0...
  • Page 6: Resistance Measurement

    reSIStAnCe MeASureMent WArnIng: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords. 1. Set the function switch to the position. 2. Press the MODE button to indicate Ω on the display. 3. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading. 4. Read the resistance in the display COntInuItY CHeCK WArnIng: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them. 1. Set the function switch to the position. 2. Press the MODE button to indicate on the display 3. Touch the test probe tips to the circuit or wire you wish to check. 4. If the resistance is less than approximately 150Ω, the audible signal will sound. If the circuit is open, the display will indicate “OL”. DIODe teSt 1. Set the function switch to the position. 2. Press the MODE button to indicate on the display. 3. Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V. Reverse voltage will indicate “Ol”. Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow Shorted devices will indicate near 0V and an open device will indicate Red - 10/100/100/5...
  • Page 7: Non-Contact Ac Voltage Measurements

    non-Contact AC Voltage Measurements WArnIng: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation. 1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 2. If AC voltage is present, the detector light will illuminate. nOte: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. nOte: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation Hold Button The Data Hold function allows the meter to “freeze” a measurement for later reference 1. Press the “DAtA HOlD” button to “freeze” the display, the “HOlD” indicator will appear. 2. Press the “DAtA HOlD” button to return to normal operation. Flashlight Press and hold the top button to turn the flashlight on. Release the button to turn the flashlight off. AutO POWer OFF The auto off feature will turn the meter off after 15 minutes. Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow Red - 10/100/100/5 Pantone 485 Red...
  • Page 8: Replacing The Battery

    rePlACIng tHe BAtterY 1. Remove the bottom cover and secure the screw. 2. Replace old battery with fresh Two 1.5V AAA type battery. 3. Replace the bottom cover and secure the screw. rePlACIng tHe FuSe 1.Disconnect the test leads from the meter. 2.Remove the test leads holder and top cover one screw. 3.Pull the pcb. 4.Lift the center circuit board straight up from the connectors to gain access to the fuse holders. 5.Gently remove the old fuse and install the new fuse into the holder. 6.Always use a fuse of the proper size and value (0.2A/250V fast blow for the 200mA range). 7.Align the center board with the connectors and gently press into place. 8.Replace and secure the rear cover and screw. WArnIng: To avoid electric shock, do not operate your meter until the fuse cover is in place and fastened securely. Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow Red - 10/100/100/5 Pantone 485 Red Yellow - 0/27/100/0 Pantone 123 Yellow Blue - 100/80/30/5...
  • Page 9 notes _________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow ________________________________________________ Red - 10/100/100/5 Pantone 485 Red Yellow - 0/27/100/0 Pantone 123 Yellow Blue - 100/80/30/5 Pantone 534 Blue...