Appendix A- HML-C AND HMLV-C

HML-C and HMLV-C furnaces may be used with the following oil burners.
Please note: The Beckett AF, and Riello 40F oil burners are for applications using indoor air for combustion only.
For sidewall venting applications utilizing outdoor air for combustion, use the Beckett AFII or the Riello 40BF
(Balanced Flue) oil burners only.
Furnace
Output
Model
BTU/Hr
2
HML-60C
59,000
HMLV-60C ²
HML-80C
75,000
HMLV-80C
HML-90C
86,000
HMLV-90C
HML-100C
95,000
HMLV-100C
1
Head is shielded by ceramic insulator.
nozzle.
(For use with sidewall vented units with outdoor combustion air, or chimney vented units with indoor air
Furnace
Output
Model
BTU/Hr
HML-60CB2U
63,000
HMLV-60CB2U
HML-80CB2U
75,000
HMLV-80CB2U
HML-90CB2U
86,000
HMLV-90CB2U
Table A-1 Beckett AF Oil Burner Set-Up
Beckett AF Series Oil Burners
(For use with chimney vented units only)
Burner
Nozzle
Model
AF76BNHS
0.50 / 80°A
AF76BNHS
0.65 / 80°A
AF76BNHS
0.75 / 80°A
AF76BNHS
0.85 / 70°A
2
Low Firing Rate Baffle required when using a 0.50-gallon
Table A-2 Beckett AFII Oil Burner Set-Up
Beckett AFII Series Oil Burners
for combustion)
Burner
Nozzle
Model
AFII-85
0.50 / 60°A
AFII-85
0.60 / 60°A
AFII-85
0.70 / 60°A
Pump
Flow Rate
Pressure
100
0.50
PSIG
100
0.65
PSIG
100
0.75
PSIG
100
0.85
PSIG
Pump
Pressure
120
PSIG
115
PSIG
115
PSIG
10
1
Head
F3
USGPH
F3
USGPH
F3
USGPH
F3
USGPH
Flow Rate
Head
0.55
USGPH
0.65
USGPH
0.75
USGPH
30173 Rev B 4/29/2008
Static
Plate
3- ⅜ in.
3- ⅜ in.
3- ⅜ in.
3- ⅜ in.
FB0
FB3
FB3