Sanyo PLC-XD2200 Service Manual page 46

Multimedia projector
Hide thumbs Also See for PLC-XD2200:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
9 DIMMER_CTRL_LEVEL10
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL12
12 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15
DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level
19 DIMMER_LEVEL_ECO
20 Lamp check enable
21 VOLTAGE_LEVEL
22 DIMMER_LEVEL_HIGH
2 Past Calculation System
24 New APL System
25 Red Average Level
26 Green Average Level
27 Blue Average Level
29 SAT
29 Chroma Coefficient
0 cSatMin
1 cSatMax
2 wCoeMin
 wCoeMax
Group
VBI Slice level
231
0 Generic Initial Slicing Level
1 Generic High Level Threshold PW190 register 0xE45
2 Generic Low Level Threshold PW190 register 0xE46
 Generic Minimum Low Level PW190 register 0xE47
4 Generic Maximum High Level PW190 register 0xE48
Group
FAN control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
 FAN2 MAX ADJUST (DAC)
4 FAN MIN ADJUST (DAC)
5 FAN MAX ADJUST (DAC)
6 Not used
7 Not used
8 Href
9 Vref
Group
251
Not used
Group
FAN option
252
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN MANUAL VOLTAGE
Function
Luminance Level 10 Data for Dimmer:
Dim Level 10 at the less than the
Value
Luminance Level 11 Data for Dimmer:
Dim Level 11 at the less than the
Value
Luminance Level 12 Data for Dimmer:
Dim Level 12 at the less than the
Value
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
Luminance Level 14 Data for Dimmer:
Dim Level 14 at the less than the
Value
Luminance Level 15 Data for Dimmer:
Dim Level 15 at the less than the
Value
Luminance Data Avarage Point for
Mimmer
Luminance Data Avarage Value for
Dimmer
Current Dimmer Leverl
Eco Dimmer Level
Lamp Voltage
Dimmer level High
PW190 register 0xE44
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
Initial
70
77
84
91
98
105
4
-
-
12/7
1/1
0
-
15/12
-
-
-
-
-
-
160
5
20
400
1000
9
0
0
0
255
8
2
8
20
18
240
100
00
0
0
0
100
100
100
-46-
range
Note
0-255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 16
-
* Read only
-
* Read only
0 - 15
(PLC-XD2600/PLC-XD2200)
0 - 15
(PLC-XD2600/PLC-XD2200)
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
Unit: 8bit(Raw Data) * Read only
0 - 15
(PLC-XD2600/PLC-XD2200)
-
-
-
-
-
-
0-255
0-255
0-255
0-1000
0-1000
0-255
0-255
0-255
0-255
0-255
0 - 255
0 - 255
0 - 255
0 - 255
0-255
0-255
0 - 9999
0 - 999
0 - 5
0 - 6
0 - 
0 - 255
0 - 255
0 - 255