Load Batteries (R03/Lr03 × 2); Installing The Remote Controller Holder; Function Setting; Operation Method - Fujitsu Ceiling Type Installation Manual

Indoor unit floor/ceiling type air conditioner
Table of Contents

Advertisement

2. Mount the cover plate (left)
Join the cover plates (left) and mount with the screw (M4 × 10).
3. Mount the intake grille
(1)
Cut the right side of the intake grille. This is only when the pipe exits from the right side.
(2)
Insert the hinges on the bottom of the intake grille into the holes in the base assembly.
Then mount the arms to the 3 areas on the top of the intake grille.
8. REMOTE CONTROLLER SETTING
Refer to the installation manual enclosed with the remote controller when the wired
remote controller (option) is used.
8.1. Load batteries (R03/LR03 × 2)
(1)
Press and slide the battery compartment lid on the reverse side to open it. Slide in the
direction of the arrow while pressing the
(2)
Insert batteries.
Be sure to align the battery polarities (
(3)
Close the battery compartment lid.
Take care to prevent infants from accidentally swallowing batteries.
When not using the Remote Controller for an extended period, remove the batteries to
avoid possible leakage and damage to the unit.
If leaking battery fl uid comes in contact with your skin, eyes, or mouth, immediately
wash with copious amounts of water, and consult your physician.
Dead batteries should be removed immediately and disposed of properly, either in a
battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.
NOTE
Never mix new and used batteries, or batteries of different types.
Batteries should last about 1 year under normal use. If the Remote controller's operating
range becomes appreciably reduced, replace the batteries and press the RESET button
with the tip of a ballpoint pen or other small object.
En-9
Cover plate (Left)
mark.
) correctly.
CAUTION

8.2. Installing the remote controller holder

Check that the indoor unit correctly receives the signal from the remote controller, then
install the remote controller holder.
Select the remote controller holder selection site by paying careful attention to the
following: Avoid places in direct sunlight. Select a place that will not be affected by the
heat from a stove, etc.
Install the remote controller with a distance of 7 m between the remote controller and
the photocell as the criteria. However, when installing the remote controller, check that it
operates positively.
Install the remote controller holder to a wall, pillar, etc., with the tapping screw.
(1)
Mount the holder.
(2)
Set the remote controller.
(3)
To remove the remote controller (when use at hand).
(1)
(2)
Press in
Screws

9. FUNCTION SETTING

Confi rm whether the wiring work for outdoor unit has been fi nished.
Confi rm whether the cap for electric control box on the outdoor unit is close.
This procedure changes to the function settings used to control the indoor unit according
to the installation conditions. Incorrect settings can cause the indoor unit malfunction.
After the power is turned on, perform the "FUNCTION SETTING" according to the instal-
lation conditions using the remote controller.
The settings may be selected between the following two: Function Number or Setting
Value.
Settings will not be changed if invalid numbers or setting values are selected.
Refer to the installation manual enclosed with the remote controller when the wired
remote controller (option ) is used.
9

9.1. Operation method

While pressing the FAN button and SET TEMP. (
button to enter the function setting mode.
STEP 1
Selecting the Remote Controller Signal
Code
Use the following steps to select the signal code of the
remote controller. (Note that the air conditioner cannot
receive a signal code if the air conditioner has not been
set for the signal code.)
The signal codes that are set through this process are
applicable only to the signals in the FUNCTION SETTING.
For details on how to set the signal codes through the
normal process, refer to Remote controller signal code.
(1)
Press SET TEMP. (
) (
) button to change the
signal code between
code on he display to the air conditioner signal code.
(initially set to
) (If the signal code does not need
to be selected, press the MODE button and proceed
to STEP 2.)
(2)
Press the TIMER MODE button and check that the
indoor unit can receive signals at the displayed signal
code.
(3)
Press the MODE button to accept the signal code, and
proceed to STEP 2.
The air conditioner signal code is factory-set to A .
Contact your retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the remote controller
are replaced. If you use a signal code other than signal code A, reset the signal code
after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the signal codes
(
) until you fi nd the code which operates the air conditioner.
CAUTION
(3)
Slide up
Insert
Pull out
CAUTION
) simultaneously, press the RESET
Match the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Floor typeAbyg24lvta

Table of Contents