4. To go to the next adjustment item or go back to the previous, press the "CHANNEL I • K" key while adjustment value is selected.
5. To go back to the aging mode, press the TEST key twice.
5. List of Electrical Adjustment
* Items not shaded in the following tables show fixed adjustment values. Input the reference value to each adjustment item.
Inputting wrong value may cause malfunction.
• If a mono-scope signal oscillator is not available for the adjustment that requires mono-scope signals, use the image signals of test tapes,
TTV-06T (PAL 625 LINE) and TTV-N06T (NTSC 525 LINE) played by VCR. Be sure the color system for input signal (VCR output
signal).
• In this manual, the values measured with SHIBASOKU-made mono-scope and the percentages of screen size are used as the adjustment
values of screen size measured with a mono-scope (PAL/NTSC). When a different model is used, calculate measured values in percentage.
• In this manual, the values measured with LEADER-made LCG-404 (PAL/SECAM) and LCG-401 (NTSC) are used as the simple
adjustment values of screen size measured with a pattern generator.
Channel
K
(Adjustment Menu Screen) : This initial values are used as reference and are considered as approximate
TV–AS216
Precautions taken before adjustment
adjustment. For normal repair, check and adjust only applicable parts.
REFERENCE VALUE
– 40 –
Channel
I
No adjustment necessary
No adjustment necessary
No adjustment necessary
No adjustment necessary
No adjustment necessary
No adjustment necessary
No adjustment necessary
No adjustment necessary