Kenwood TS-570D, TS-570S Instruction Manual page 83

Kenwood multi-bander ts-570d, hf transceiver ts-570d instruction manual
Hide thumbs Also See for TS-570D, TS-570S:
Table of Contents

Advertisement

FW
FILTER WIDTH
Sets or reads filter bandwidth.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
F W
P1
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
F W ;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
F W
P1
;
GT
AUTO GAIN CONTROL TIME CONSTANT
Sets or reads AGC time constant.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
G T
P1
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
G T
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
G T
P1
;
ID
IDENTIFICATION
Reads Model number of the transceiver.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
D
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
D
P1
;
IF
INFORMATION
Reads status of the transceiver.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
F
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
F
P1
15 16 17 18 19 20 21 22 23 24 25 26 27 28
P3
29 30 31 32 33 34 35 36 37 38 39 40 41 42
P8 P9 P10 P11 P12 P13 P14
IS
IF SHIFT
Sets or reads IF shift.
1 2
3 4 5 6 7 8
9 10 11 12 13 14
I
S P1
P2
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
S
;
1 2 3 4 5 6 7 8
9 10 11 12 13 14
I
S P1
P2
;
Parameter Format Parameter function
P1
38
FILTER WIDTH
Note:
CW
SSB/AM/FM
0000~0079: 50 Hz
0000: Narrow
0080~0099: 80 Hz
0001~: Wide
0100~0149: 100 Hz
0150~0199: 150 Hz
FSK
0200~0299: 200 Hz
0000~0499: 250 Hz
0300~0399: 300 Hz
0500~0999: 500 Hz
0400~0499: 400 Hz
1000~1499: 1000 Hz
0500~0599: 500 Hz
1500~
0600~0999: 600 Hz
1000~1999: 1000 Hz
2000~
: 2000 Hz
Parameter Format Parameter function
P1
39
AGC TIME
CONSTANT
Note:
When in FM mode, the transceiver
returns "
".
Parameter Format Parameter function
P1
16
MODEL NUMBER
Parameter Format Parameter function
FREQUENCY
P1
4
NOT USED
P2
P3
5
RIT/XIT FREQUENCY
RIT OFF/ON
P4
1
XIT OFF/ON
P5
1
P6
NOT USED
P7
7
MEMORY CHANNEL
TX/RX
P8
11
MODE
P9
2
P10
3
FUNCTION
SCAN OFF/ON
P11
1
SPLIT OFF/ON
P12
1
P13
1
TONE OFF/ON
P4
P5
P7
P14
14
TONE NUMBER
NOT USED
P15
;
Parameter Format Parameter function
P1
40
IF SHIFT
DIRECTION
P2
41
IF SHIFT
FREQUENCY
Note:
If P2 is positive or zero, P1 can be
"+" or " ".
KS
KEYER SPEED
Sets or reads keying speed while using the KY command.
1 2
3 4 5 6 7 8
K S
P1
;
1 2 3 4 5 6 7 8
K S
;
: 1500 Hz
1 2 3 4 5 6 7 8
K S
P1
;
KY
CW KEYING
Converts input characters into Morse code.
1 2 3 4 5 6 7 8
K Y
15 16 17 18 19 20 21 22 23 24 25 26 27 28
1 2 3 4 5 6 7 8
; ;
K Y
1 2 3 4 5 6 7 8
;
K Y P2
15 16 17 18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36 37 38 39 40 41 42
LK
FREQUENCY LOCK
Sets Frequency Lock OFF/ON or reads status.
1 2
3 4 5 6 7 8
L K P1
;
1 2 3 4 5 6 7 8
L K
;
1 2 3 4 5 6 7 8
L K P1 ;
LM
LOAD MESSAGE
DRU or CW message recording
1 2
3 4 5 6 7 8
L M P1
;
1 2 3 4 5 6 7 8
L M ;
1 2 3 4 5 6 7 8
L M P1 ;
APPENDIX
Parameter Format Parameter function
P1
42
9 10 11 12 13 14
9 10 11 12 13 14
9 10 11 12 13 14
Parameter Format Parameter function
P1
43
KEYER MESSAGE
P2
44
KEYER BUFFER
Note:
The Set command requires
a "
" (ASCII code 20h) in the
9 10 11 12 13 14
third byte position. Insert "
P1
bytes that have no characters to
make a 28-byte fixed length
command.
;
The " " bytes will not send any
character.
9 10 11 12 13 14
Supported characters include:
Letters, numbers, " ' (( )) ( )
. / : = ?
9 10 11 12 13 14
Up to 24 characters can be
converted as one sentence at one
time. The subsequent sentence
must be keyed after the current
conversion is completed.
Parameter Format Parameter function
P1
1
LOCK OFF/ON
9 10 11 12 13 14
9 10 11 12 13 14
9 10 11 12 13 14
Parameter Format Parameter function
P1
45
9 10 11 12 13 14
9 10 11 12 13 14
9 10 11 12 13 14
KEYER SPEED
" for
+ ,–
LOAD
MESSAGE
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-570sTs-570g