Extension Cords; Adjustments; Belt Tension - Powermatic 15S Operating Instructions And Parts Manual

15"
Table of Contents

Advertisement

Available languages

Available languages

This machine must be grounded. Grounding
provides a path of least resistance to help divert
current away from the operator in case of
electrical malfunction.
Make sure the voltage of your power supply
matches the specifications on the motor plate of
the machine.

Extension Cords

The
use
of
an
extension
recommended for this machine, but if one is
necessary make sure the cord rating is suitable
for the amperage listed on the machine's motor
plate. An undersized cord will cause a drop in
line voltage resulting in loss of power and
overheating.
The chart in Figure 11 shows the correct size
cord to use based on cord length and motor
plate amp rating. If in doubt, use the next
heavier gauge. The smaller the gauge number
the heavier the cord.

Adjustments

Tools required for assembly:
10, 12 and 17mm open-end wrenches
3, 5 and 6mm hex wrenches
0.020" (0.5mm) feeler gauge
straight edge
gauge block
cross-point screwdriver
Disconnect machine from
power
source
before
adjustments (except feed rate).

Belt Tension

Inspect the tension of the belts frequently during
the first few times you use the planer. Belts often
stretch during this trial period. If they require
tightening, proceed as follows:
1. Remove the belt guard and the rear panel.
2. Loosen the bottom nut on the motor
adjustment screw (Figure 12) with a 17mm
wrench.
3. Turn the top nut on the adjustment screw to
lower the motor plate, which will increase
the belt tension.
4. Proper tension is achieved when there is
slight deflection in the belt midway between
the pulleys, using moderate finger pressure.
5. Tighten the bottom nut on the adjustment
screw (Figure 12).
Recommended Gauges (AWG) of Extension Cords
8 to 12
cord
is
not
12 to 15
15 to 20
21 to 30
*based on limiting the line voltage drop to 5V at 150% of the
rated amperes.
NR: Not Recommended.
making
any
10
Extension Cord Length *
25
50
75
Amps
feet
feet
feet
< 5
16
16
16
5 to 8
16
16
14
14
14
12
12
12
10
10
10
10
10
NR
NR
Figure 11
Figure 12
100
150
200
feet
feet
feet
14
12
12
12
10
NR
10
NR
NR
10
NR
NR
NR
NR
NR
NR
NR
NR