OPERATION
This storage heater takes in Energy when
electricity tariffs are low and dissipates it
when tariffs are normal.

SAFETY INSTRUCTIONS

1. Ventilate rooms well during commissioning.
2. Do not move the heater in any way once installed without
the services of a competent electrician.
3. Do not cover the heater with clothing etc. at any time or
position furniture close to or against the heater.
4. Ensure a clearance of at least 150mm between heaters and
curtains.
5. Should your heater fail to operate either employ the
services of a competent electrician or Telephone 0845
600 5111.
ALSO REFER TO COVER PAGE
COMMISSIONING
Set both the Input Control and the Output Control to 6 and
leave the heater for 48 hours.
Following the commissioning period adjust the controls as
stated below.

SETTING THE CONTROLS

The controls are located under the hinged fl ap at the top right hand
corner of the heater.
To adjust the controls on the heater use a coin and engage it in the
slots provided on the top surface of the knob. There are no user
adjustable controls on the XMX706N.
CONTROL FUNCTIONS
THE INPUT CONTROL
For models XMS712N, 718N, 724N only:
This heater is fi tted with a user adjustable automatic input control
which varies the charge taken in response to weather conditions
taking into account the amount of energy already stored in the
heater.
Set at 6 the heater takes maximum charge and at 1 the heater
takes a minimum charge at any room temperature. The casing of
the heater, particularly in late evening, may feel cool, this is quite
normal. The input control may require a few days experimentation
before your comfort level is established.
Initially set the control to 3, the following evening if the room is too
warm reduce to 2 or if it is too cool increase to 4. On subsequent
evenings adjust by half divisions until your comfort level is
achieved.
Having established the setting the input will automatically vary the
amount of heat stored to compensate for weather variations.
This product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3.
These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
© GDC Group Ltd. All rights reserved.
Material contained in this publication may not
be reproduced in whole or in part, without prior
permission in writing.
A division of the GDC Group Ltd, Millbrook House,
Grange Drive, Hedge End, Southampton SO30 2DF
85149 Issue 9 : 06/09
For models XMX712N, 718N, 724N only:
Initially set the input to 4. If the heater does not maintain a
satisfactory room temperature the following day this setting should
be increased. Conversely if the room temperature is too high this
setting should be reduced.
The input control should only require seasonal adjustments.
Most of the stored heat is radiated from the casing during the
discharge period. However, some of the heater is emitted
through the grille at the top of the heater and this additional heat
(or boost) is regulated by the Output Control.
With this set to 6 the boost begins in the early afternoon. Turning
the control towards 1 will progressively delay the commencement
of the boost. At 3 the boost will start in the evening. Once set,
the boost will repeat itself automatically day after day.
If no boost is required e.g. when the room will be unoccupied
for a long period, set the Output Control to 1. With the control
in this position, the heater will take less energy during the next
charging up period.
To maintain the appearance of the heater wipe occasionally with a
dry cloth when the heater is cool.
Do not use abrasive powders of furniture polish.
Discolouration of wall fi nishes can sometimes occur immediately above
a storage heater due to the properties of some paints and decorating
materials or the presence of environmental impurities in the air (such
as soot or incense generated from the burning of candles, etc.)
Your product is guaranteed for two years from date of purchase.
Within this period, we undertake to repair or exchange free of charge
provided it has been installed and operated in accordance with
these instructions. Your rights under this guarantee are additional
to your statutory rights, which in turn are not affected by this
guarantee. Should you require after sales information please go to
www.dimplex.co.uk where you will fi nd our self help guide by clicking
on 'After Sales' or ring our help desk on 0845 600 5111 (UK) or
01842 4833 (ROI). Spare parts are also available on the website
www.dimplex.co.uk.
Please do not initially return faulty appliance, or part of an appliance, to us
as this may result in transit damage and/or a delay in providing service.
Let us know your diffi culty quoting the model number and serial
number (located along the wall bracket). We will then take
the appropriate action. Please retain your receipt as proof of
purchase.
Authority or retailer for recycling advice in your country.
Dimplex UK Limited,
Millbrook House,
Grange Drive,
Hedge End,
Southampton,
SO30 2DF.
THE OUTPUT CONTROL
For all models except XMX706N
CLEANING
AFTER SALES SERVICE
RECYCLING
For electrical products sold within the European
Community. At the end of the electrical products useful
life it should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local
Tel:
Fax:
Web-site
Republic of Ireland
0845 600 5111
01489 773 050
www.dimplex.co.uk
01 842 4833

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Xms/x718nXms/x712nXms/x724nXms718nXmx718nXms712n ... Show all