7.0 FLUE SPILLAGE MONITORING SYSTEM

This fire is fitted with a flue spillage safety device (ODS).
If the fire shuts down during use for no apparent reason then several reasons may be suspected. If a door or window has been
opened creating a draught, then pilot disturbance could be the problem, and removal of the draught should resolve this.The fire
can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your
installer to check any ventilation and carry out any remedial work required. DO NOT allow the appliance to be used until the
installation is passed as safe.
8.0 FUEL BED LAYOUT (COAL EFFECT)
Full depth coal effect models
1. Position the combustion matrix onto the burner tray as shown in
figure 6. The front edge of the matrix should sit snugly behind the
back edge of the burner rails as shown in figure 7. Do not fit the
matrix on top of the burner rails.
2. Position the front coal strip as shown in figure 8.The rear edge of
the front coal strip should fit in front of the burner rail.Again, do not
place on top of the burner rails. When the front coal is in position
bend up the three metal tags at the front of the tray to retain as
shown in figure 8a.
3. Coals.All of the coals are the same.Take five coals and place them
as shown in figure 9. Care should be taken to ensure that the coals
bridge the gap between the front coal and the four coal supports at
the front of the matrix. Care should also be taken not to push the
coals right down between the coal supports, as this can detract from
the flame picture when the appliance is running.
Figure 8a
4
Figure 6
Figure 7
Incorrect
Figure 8
Figure 9
GB IE
Correct
2013 Focal Point Fires plc.
'