Trouble Shooting Guide; For Standard Installation - Panasonic CS-F24DD2E5 Service Manual

Panasonic air conditioner service manual
Hide thumbs Also See for CS-F24DD2E5:
Table of Contents

Advertisement

12 TROUBLE SHOOTING GUIDE

If test operation does not proceed correctly
Carry out test operation after approximately 12 hours have passed since the power was turned on (crankcase heater is energized). If operation
is started by using the remote control within 1 minute of turning on the power, the outdoor unit settings will not be made correctly and correct
operation will not be possible.
If the following symptoms occur after turning on the power, check the wiring connections once more.

12.1. For standard installation

System example
1. The main power is turned on while the indoor-outdoor transmission wires are not connected.
(open circuit at A: power line)
Symptom
Indoor unit : no power supply
Remote control unit : no power supply
Outdoor unit : LED2, 4, 6 on P.C.B flashes
2. The main power is turned on while the indoor-outdoor transmission wires are not connected.
(open circuit at B: power/transmission line)
Symptom
Indoor unit : no power supply
Remote control unit : no power supply
Outdoor unit : LED2, 4, 6 on P.C.B flashes
3. The main power is turned on while the indoor-outdoor transmission wires are not connected.
(open circuit at C: transmission line)
Symptom
Remote control unit : "check" flashes
Error code : F27-01 (indoor/outdoor transmission error)
Indoor unit : LED1 on P.C.B flashes
Outdoor unit : LED2, 4, 6 on P.C.B flashes
85