Dip Switch Setting; Led Indicators - Weidmuller IE-MC-VL Series Hardware Installation Manual

Table of Contents

Advertisement

Dip Switch Setting

IE-MC-VL Series DIP switch
ON
DIP
1
2
3
To activate the updated DIP switch settings, power off and then
power on the Media Converter.

LED Indicators

The front panel of the Media Converter contains several LED
indicators. The function of each LED is described in the table below.
LED
AMBER
PWR1
AMBER
PWR2
FAULT
GREEN
10M
GREEN
100M
Dip Switch 1 (Default: Off )
ON: Enables the PORT Alarm. If the port's link fails,
the relay will form an open circuit and the fault
LED will light up.
Off: Disables the corresponding PORT Alarm. The
relay will form a closed circuit and the Fault
LED will never light up.
Dip Switch 2 (Default: ON )
ON: Enables full duplex for 100BaseFX
Off: Disables full duplex for 100BaseFX
Dip Switch 3
Reserved for future use
Color
State
RED
Blinking
Power is being supplied to
On
power input PWR1
Power is not being supplied
Off
to power input PWR1
Power is being supplied to
On
power input PWR2
Power is not being supplied
Off
to power input PWR2
When the corresponding
PORT alarm is enabled,
On
and the port's link is
inactive.
When the corresponding
PORT alarm is enabled and
Off
the port's link is active, or
when the corresponding
PORT alarm is disabled.
TP port's 10 Mbps link is
On
active
Data is being transmitted at
10 Mbps
TP Port's 10 Mbps link is
Off
inactive
TP port's 100 Mbps link is
On
active
- 11 -