Kenmore UltraSoft 170 Installation Manual page 16

Ultrasoft water softeners with deluxe valve
Table of Contents

Advertisement

[i!i! ::i : i ! ::i : i ! ::i SECTION
3
STEP BY STEP GUIDES TO INSTALL
D. CONNECT
VALVE AND SALT TANK DRAINS
_1_
CONNECT
THE VALVE
DRAIN
HOSE
Take a length
of 3 / 8" inside
diameter
drain
tub-
ing and attach
one end to the drain
fitting
(FIG.
12). Use a tube clamp
to hold it in place.
Put the
other
end of the tubing
over a floor drain,
into a
laundry
tub, standpipe,
or other
suitable
drain.
Check
your
local codes.
Leave an air gap of about
1-1/2" between
the end
of the hose and the drain.
This gap is needed
so you
don't
get a back-flow
of sewer
water
into the soften-
er. Do not put the end of the hose
into the drain
or
connect
without
the air gap.
Place and support
the hose so it does not kink or
have sharp
bends.
So water
pressure
does not cause
the hose
to "whip",
tie or wire
it in place.
Do not
pinch
the hose
shut.
The softener
will not work
if
this drain
hose
is pinched,
plugged,
closed
or re-
stricted
in any way.
Keep
the hose
lower
than
the drain
fitting.
(In
some
homes,
to get to a drain
you must
raise
the
hose and run it over-head.
If you need
an overhead
drain,
do not raise the hose
more
than
8' above
the
floor. A copper
drain
tube
is best to use.)
COPPER
DRAIN
TUBE:
The
plumbing
codes
where
you live may say that you must
use a copper
valve drain
tube. A copper
tube is also best to use for
an over-head
drain.
Use a copper
drain
tube
if the
softener
is installed
outside,
or in the sunlight.
Heat
from the sun makes
many
kinds
of rubber
or plastic
hose to soften,
flatten
and close up.
To adapt
a copper
drain
tube to the softener,
buy
a
compression
fitting
(1/4
in. female
pipe
threads
x
1/2 in. O.D. tube) and tubing
from your
local hard-
ware
store.
DELUXE VALVE
grommet
tube
adaptor
"
_
tube
l_lamp
NOTE: Overflow
drain
tubing
is
available
from
Sears, Item No.
42 - 3433 (20 ft)
overflow
drain
--
tubing (see step 2,
top of page 3-6)
N\
x\
XX
\\
\\
NN
\\
X\
K\
N\
\x_...
To drain point
"_
other than
valve drain hose
floor drain.
(see
step 1, above)
Support
tubing
in place as
needed.
1 1/_p,
tie or wire
air gap
tubing in place
1
"
27
Optional copper drain hook-up,
check with local codes
_/_ _/L_
11/4NPT Threads
barbs
"i !
Diameter
clip
_
"::/
Copper
Tube
#
(not furnished)
cut
barbs
from drain fitting
(pull clip and remove
lilting from valve)
.2"--...
Comp Fitting, 1/4 NPT
x 1/2 in. OD. Tube
-...
(not furnished)
STANDPIPE
r gap
1-'_/' air gap
3-5
Deluxe
Valve

Hide quick links:

Advertisement

Table of Contents
loading