BEFORE
OPERATING:
• Check the gas lines for leaks•
a. Use a soapy water solution• DO NOT
test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings•
c. Check
for bubbling
soap. This
means you have a leak.
_lhrn
OFF
gas and make the necessary repairs.
d. Recheck for leaks•
e. Rinse off soapy solution and wipe dry.
• ls the new temperature-pressure
relief valve properly installed
and piped to an adequate
drain? See "_l_mperature-Pressure
Relief Valve" section•
• Are the cold and hot water lines connected
to the water
heater correctly? See "Water Piping" instructions
in the
"Installation Instructions" section.
• ls the water heater completely
filled with water? See "Filling"
instructions
in the "Installation
Instructions"
section.
• Will
a water
leak damage
anything?
See the "Facts
to
Consider About the Location" section.
• ls there proper clearance between the water heater and any-
thing that might catch fire? See the "Facts to Consider About
the Location" section.
• Do you have adequate ventilation so that the water heater
will operate properly? See "Combustion Air and Ventilation"
in the "Installation Instructions" section.
• ls the draft hood vent piping properly secured? See "Venting"
instructions in the "Installation Instructions" section.
• ls there proper clearance between the vent pipe and anything
that might catch fire. See Ventmg
mstructtons
m the
"Installation Instructions" section.
PIPE TO
OUTDOORS
HOT
VALVE
DRIP LE(
[Sediment
trap)
PIPE I
GAS
SUPPLY
SHUTOFF
VALVE
PRESSURE
RELIEF VALVE
PiPE
(Do not cap or plug)
g
• ls the vent pipe properly sloped and does the vent terminate
outdoors• See Venting
mstructmns
m the
Installatmn
Instructions
section.
• Do you need to call your gas company
to check the gas pipe
and its hookup?
CHECK
FOR
LEAKS
Be sure to check all your gas pipes for leaks before operating
your water heater. Use a soapy water solution, not a match or
open flame. Check the factory gas fittings after the main burner
is turned "ON". Use a soapy water solution for this, too.
SLII'I_&BLI: F OR WATER (PGTABI.E)
HEATING ONLY
EGt_PPED
F_
k_PLt¢
RECOVERy
_IAL
Nt/MS_
I
I
I
GAS
BTU_
GALPAR
MAXIMU_
HyD_TATIC
GAS
pRE_RE
IN W C
_ N T_NG
*
,so
I
I
PNI
WC
WC
WC
AUTOMATIC STORAGE WATER HEATER
ELECTRICAL RATING: VOLTS 115!HZ60/AMPS 2
MODEL RATING PLATE
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents