Gas Piping - Kenmore THE ECONOMIZER 153.332861 Owner's Manual

Power vent gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
ALL
MODELS
-- THROUGH
ROOF
3°"DIA.VENT
MAX. LENGTH (FT.)
115
II0
105
100
95
9O
NUMBER OF 90 ° DEG.
ELBOWS •
I
2
3
4
5
6
ALL MODELS m THROUGH
ROOF
OPTIONAL
2" VENT PIPING
2" DIA.VENT
MAX. LENGTH
{FT.)
5O
45
4O
35
3O
25
NUMBER
OF 90 ° DEG.
ELBOWS •
I
2
3
4
5
6
* NOTE: Two 45 ° elbows are equivalent
to one 90 ° elbow.
One 90 ° elbow equals 5 feet of equivalent
vent length.
Gas Piping
A gas line of sufficient size must be run to the water heater.
Consult the current edition of National Fuel Gas Code ANSI
Z223.1, also referred to as NFPA 54 and the gas company con-
cerning pipe size.
There must be:
• A readily accessible manual shut off"valve in the gas supply
line serving the water heater, and
• A drip leg (sediment trap) ahead of the gas control valve to
help prevent dirt and foreign materials from entering the gas
control valve.
• A flexible gas connector
or a ground joint union between the
shutoffvalve and control valve to permit servicing of the unit.
Be sure to check all the gas piping
for leaks before lighting the
water heater. Use a soapy water solution,
not a match or open
flame. Rinse offsoapy
solution and wipe dry.
Standard
Models
are for installation
up to 3,300 feet above sea
level.
High Altitude Models are for installation from 3,300 to 5,500
feet above sea level.
lfa standard model is installed above 3,300 feet or a high altitude
model is installed above 5,500 feet, the input rating must be
reduced at the rate of 4 percent for each 1,O00 feet above sea level
which requires replacement of the burner orifice in accordance
with the National Fuel Gas Code Z223.1, NFPA 54. Contact the
local Sears Service Center or your local gas utility for further
information.
_WARNING
Hake sure the gas supplied is the same type listed on
the model
rating plate.
The inlet gas pressure
must
not exceed
10.5 in. water
column
(2.6 kPa) for natu-
ral gas or 13 in. water
column
(3.2 kPa) for Propane
(L.R)
gas. The
minimum
inlet gas pressure listed on
the model
rating
plate
is for the purpose
of input
adjustment.
AWARNING
I
If the
gas control
valve
is subjected
to pressures
exceeding
½ pound
per square
inch (3.5kPa),
the I
damage
to the gas control
valve could result in a fire
or expos
on from
eak ng gas.
AWARNING
If the main gas line shutoff serving all gas appliances
is used, also turn
"off"
the gas at each appliance.
Leave
all gas appliances
shut
off until
the water
heater
installation
is complete.
AWARNING
Failure
to replace
the standard
orifice
with
a high
altitude
orifice
when
installed
at elevations
above
3,300
feet
(or above
5,500
feet
for high
altitude
model),
could
result
in improper
and inefficient
operation
of the appliance,
producing
carbon monox-
ide gas in excess of safe limits, which could result
in
serious
injury
or death.
Contact
the
local
Sears
Service
Center
or your gas supplier
for any specific
changes which may be required
in your area.
AWARNING
J
The
appliance
and its gas connection
must
be leak
tested
before
placing the appliance
in operation.
23