Installation
Instructions
(cont'd)
Gas Piping (cont'd)
,&WARNING
The appliance
and its individual
shutoff valve must
be disconnected
from
the gas supply piping
sys-
tem
during any pressure
testing
of the gas system
at test pressures
in excess of I/2 pound per square
inch (3.5kPa).
The
appliance
must
be isolated
from the gas sup-
ply piping system
by closing its individual
manual
shutoff valve during any pressure testing
of the gas
supply
piping
system
at test
pressures
equal
or
less than I/2 pound per square inch (3.5kPa).
_,WARNING
I
Use pipe joint compound or teflon tape marked as I
being resistant to the action of petroleum
[Propane
(L.R)] gases.
Connecting
the gas piping to the gas control valve of the water
heater can be accomplished
by either of the two methods shown.
GAS PIPING
WITH
FLEXIBLE
CONNECTOR
GAS SUPPLY PIPING
g. u"Uo
VALVE _
GROUND
UNION
(OPTIONAL)
FLEXIBLE GAS CONNECTOR
LABELED AS COMPLYING
WITH
ANSI STANDARDS
SEDIMENT
TRAP
A sediment
trap shall be installed
as close to the inlet of the
water heater as practical
at the time of water heater installation.
The sediment trap shall he either a tee fitting with a capped nip-
ple in the bottom
outlet or other device recognized
as an effec-
tive sediment
trap. If a tee fitting is used, it shall be installed
in
conformance
with one of the methods of installation
shown.
DRIP LEG
(SEDIMENT
GAS
3" MIN.
TRAP)
....._ _ _,
CONTROL
VALVE
1 CAP
_,WARNING
Contaminants
in the gas lines may cause improper
operation
of the gas control
valve that may result
in
fire or explosion.
Before
attaching
the gas line be
sure that all gas pipe is clean on the inside. To trap
any dirt or foreign
material
in the gas supply line, a
drip leg (sometimes
called a sediment
trap)
must
be
incorporated
in the
piping.
The
drip
leg must
be
readily
accessible. Install in accordance
with the "Gas
Piping"
section.
Refer
to the current
edition
of the
National
Fuel Gas Code,
ANSI
Z223.1,
also referred
to as NFPA 54.
GAS PIPING
WITH
ALL BLACK
IRON
PIPE
TO GAS CONTROL
GAS SUPPLY PIPING
gH gTUo h
VALVE _
GROUND
JOINT
UNION
3"MIN.
BLACK PIPE
DRIPLEG _
GAS
($EDIMENTIL_ _J
_"
.1
CONTROL
TRAP)
VALVE
ICAP
24