Air Flow Data - Goodman MVC8 Installation Instructions Manual

Gas furnace
Table of Contents

Advertisement

A
F
D
IR
LOW
ATA
Speed Selection Dip Switches
Cool
Adjust
Selection
Selection
Switches
Switches
TAP
S3- 1 S3- 2 S3- 3 S3- 4 S4-1 S4-2
A
OFF
OFF OFF OFF
B
ON
OFF
ON
OFF
C
OFF
ON OFF
ON
OFF
D
ON
ON
ON
ON
Profiles
Pre-Run
Short-Run
A
-------
--------
B
-------
30 sec/50%
C
-------
7.5 min/82%
D
30 sec/50%
7.5 min/82%
To Set Airflow: (1) Select model and desired High Stage Cooling Airflow. Determine
the corresponding tap (A, B, C, or D). Set dip switches S3-1* and S3-2* to the
appropriate ON / OFF positions. (2) Select model and desired High Stage Heating
Airflow. Determine the corresponding tap (A, B, C, or D). Set dip switches S4-3* and
S4-4* to the appropriate ON / OFF positions. (3) Selecting Airflow Adjustment Factor:
For 0% trim set S5-2* to OFF (trim disabled). If trim is desired set S5-2* to ON (trim
enabled) and set S3-3* and S3-4* to appropriate ON / OFF positions. Tap A is +5%,
Tap B is -5%, Tap C is +10%, Tap D is -10%.
To Set Comfort Mode: Select Desired Comfort Mode profile (see profiles above). Set
dip switches S4-1* and S4-2* to the appropriate ON / OFF positions.
Dehumidification: To enable, set switch S5-1* to ON. Cooling airflow will be reduced
to 85% of nominal value during cool call. To disable, set switch S5-1* to OFF.
Continuous Fan Speed: Set dip switches S5-3* and S5-4* to select one of 4
continuous fan speeds (25%, 50%, 75%, or 100%). " See installation manual
for details"
*the "S" number refers to one of four labeled dip switch section each containing 4
individual dip switches. The following number refers to the individual labeled dip
switch within that section
NOTE: Airflow data shown applies to non-communicating mode operation only. For a fully communicating
system, please see the outdoor unit's installation instructions for cooling and pump heating airflow data. See
ComfortNet™ System - Airflow Consideration section for details.
Model
Profile
Heat
Selection
Selection
Switches
Switches
*DVC80603B***
S4- 3 S4- 4
OFF OFF
OFF
OFF
ON
OFF
ON
OFF
*DVC80805C***
ON
OFF
ON
ON
ON
ON
ON
OFF Delay
60 sec/100%
*DVC81005C***
60 sec/100%
60 sec/100%
30 sec/50%
*MVC80604B***
*MVC80805C***
*MVC81005C***
0140F01170
Tap
Low Stage
High Stage
Cool
Cool
A
390
B
520
C
650
1000
D
780
1200
A
520
B
715
C
910
D
1170
A
553
B
748
C
943
D
1203
A
390
600
B
520
C
715
1100
D
910
1400
A
520
B
715
C
910
D
1170
A
520
B
715
C
910
1400
D
1170
1800
46
Low Stage
Heat
600
735
800
805
875
945
800
945
1100
1015
1400
1085
1800
1155
850
1085
1150
1155
1450
1225
1850
1260
875
800
945
1015
1085
800
1050
1100
1120
1400
1190
1800
1260
800
1210
1100
1225
1245
1260
High Stage
Heat
1050
1150
1250
1350
1350
1450
1550
1650
1550
1650
1750
1800
1250
1350
1450
1550
1500
1600
1700
1800
1725
1750
1775
1800