Circulator Blower Speeds - Goodman MVC8 Installation Instructions Manual

Gas furnace
Table of Contents

Advertisement

HEAT EXCHANGER
RADIATION "LINE OF SIGHT"
Temperature Rise Measurement
C
B
S
IRCULATOR
LOWER
PEEDS
T
 
 
 
 
O
AVOID
PERSONAL
INJURY
 OFF 
 
 
 
TURN
POWER
TO
THE
FURNACE
Speed Selection Dip Switches
Cool
Adjust
Selection
Selection
Switches
Switches
TAP
S3- 1 S3- 2 S3- 3 S3- 4 S4-1 S4-2
A
OFF
OFF OFF OFF
B
ON
OFF
ON
OFF
C
OFF
ON OFF
ON
D
ON
ON
ON
ON
Profiles
Pre-Run
A
-------
B
-------
C
-------
D
30 sec/50%
To Set Airflow: (1) Select model and desired High Stage Cooling Airflow. Determine
the corresponding tap (A, B, C, or D). Set dip switches S3-1* and S3-2* to the
appropriate ON / OFF positions. (2) Select model and desired High Stage Heating
Airflow. Determine the corresponding tap (A, B, C, or D). Set dip switches S4-3* and
S4-4* to the appropriate ON / OFF positions. (3) Selecting Airflow Adjustment Factor:
For 0% trim set S5-2* to OFF (trim disabled). If trim is desired set S5-2* to ON (trim
enabled) and set S3-3* and S3-4* to appropriate ON / OFF positions. Tap A is +5%,
Tap B is -5%, Tap C is +10%, Tap D is -10%.
To Set Comfort Mode: Select Desired Comfort Mode profile (see profiles above). Set
dip switches S4-1* and S4-2* to the appropriate ON / OFF positions.
Dehumidification: To enable, set switch S5-1* to ON. Cooling airflow will be reduced
to 85% of nominal value during cool call. To disable, set switch S5-1* to OFF.
Continuous Fan Speed: Set dip switches S5-3* and S5-4* to select one of 4
continuous fan speeds (25%, 50%, 75%, or 100%). " See installation manual
for details"
*the "S" number refers to one of four labeled dip switch section each containing 4
individual dip switches. The following number refers to the individual labeled dip
switch within that section
NOTE: Airflow data shown applies to legacy mode operation only. For a fully communicating system, please see the
outdoor unit's installation instructions for cooling and pump heating airflow data. See ComfortNet™ System - Airflow
Consideration section for details.
SUPPLY
AIR
T
SUPPLY
T
T
RISE =
-
SUPPLY
RETURN
T
RETURN
RETURN
AIR
WARNING
 
 
 
 
 
OR
DEATH
DUE
TO
ELECTRICAL
SHOCK
 
 
 
BEFORE
CHANGING
SPEED
Profile
Heat
Selection
Selection
Switches
Switches
*DVC80603B***
S4- 3 S4- 4
OFF OFF
OFF
OFF
ON
OFF
ON
OFF
*DVC80805C***
OFF
ON
OFF
ON
ON
ON
ON
ON
Short-Run
OFF Delay
--------
60 sec/100%
*DVC81005C***
30 sec/50%
60 sec/100%
7.5 min/82%
60 sec/100%
7.5 min/82%
30 sec/50%
*MVC80604B***
*MVC80805C***
*MVC81005C***
0140F01170
This furnace is equipped with a multi-speed circulator blower.
This blower provides ease in adjusting blower speeds. The
Specification Sheet applicable to your model provides an air-
flow table, showing the relationship between airflow (CFM) and
external static pressure (E.S.P.), for the proper selection of
heating and cooling speeds. The heating blower speed is
shipped set at "B", and the cooling blower speed is set at "D".
These blower speeds should be adjusted by the installer to
match the installation requirements so as to provide the cor-
rect heating temperature rise and correct cooling CFM.
Use the dual 7-segment LED display adjacent to the dipswitches
to obtain the approximate airflow quantity. The airflow quantity
is displayed as a number on the display, rounded to the near-
est 100 CFM. The display alternates airflow delivery indication
and the operating mode indication.
Example: The airflow being delivered is 1225 CFM. The dis-
play indicates 12. If the airflow being delivered is 1275, the
display indicates 13.
1. Determine the tonnage of the cooling system installed
with the furnace. If the cooling capacity is in BTU/hr divide
it by 12,000 to convert capacity to TONs.
Example: Cooling Capacity of 30,000 BTU/hr.
 
.
TAPS
Model
Tap
Low Stage
Cool
A
390
B
520
C
650
D
780
A
520
B
715
C
910
D
1170
A
553
B
748
C
943
D
1203
A
390
B
520
C
715
D
910
A
520
B
715
C
910
D
1170
A
520
B
715
C
910
D
1170
28
30,000/12,000 = 2.5 Tons
High Stage
Low Stage
Cool
Heat
600
735
800
805
1000
875
1200
945
800
945
1100
1015
1400
1085
1800
1155
850
1085
1150
1155
1450
1225
1850
1260
600
875
800
945
1100
1015
1400
1085
800
1050
1100
1120
1400
1190
1800
1260
800
1210
1100
1225
1400
1245
1800
1260
High Stage
Heat
1050
1150
1250
1350
1350
1450
1550
1650
1550
1650
1750
1800
1250
1350
1450
1550
1500
1600
1700
1800
1725
1750
1775
1800