Safety Precautions - Kenmore 153 Owner's Manual

Kenmore water heater user manual
Hide thumbs Also See for 153:
Table of Contents

Advertisement

Thank Youforpurchasing a Kenmore waterheater. Properly
installed and maintained,
itshould g ive youyears o ftrouble f ree
service. Ifyou should d ecide t hatyou want t henew water h eater
professionally
installed bySears c all1-800-4-MY-HOME_L
They
willarrange forprompt, quality i nstallation bySears a uthorized
contractors.
Abbreviations Found In
This
Instruction
Manual:
CSA - Canadian
Standards
Association
ANSI
-American
National
Standards
Institute
NFPA - National
Fire Protection
Association
ASME
- American
Society
of Mechanical
Engineers
GAMA
- Gas Appliance
Manufacturers
Association
This
gas-fired
water
heater
is design
certified
by CSA
INTERNATIONAL
under
American
National
Standard/CSA
Standard
for Gas Water
Heaters
ANSI
Z21.10.1
• CSA 4.1
(current
edition).
Read the "Safety
Precautions"
section,
page 3 of this manual
first and then the entire
manual
carefully.
If you don't follow
the safety rules,
the water
heater
will not operate
properly.
It
could
cause
DEATH,
SERIOUS
BODILY
INJURY
AND/OR
PROPERTY
DAMAGE.
This manual contains
instructions
for the installation,
operation,
and maintenance
of the gas-fired
water
heater. It also contains
warnings
through
out the manual
that you must read and be
aware
of. All warnings
and all instructions
are essential
to the
proper
operation
of the water
heater
and your
safety.
Since
we cannot
put everything
on the first few pages,
READ
THE
ENTIRE
MANUAL
BEFORE
ATTEMPTING
TO INSTALL
OR
OPERATE
THE WATER
HEATER.
The installation
must conform
with these
instructions
and the
local
code
authority
having
jurisdiction.
In the absence
of
local codes,
installations
shall comply
with the following:
The National
Fuel
Gas Code ANSI
Z223.1/NFPA
54.
This
publication
is available
from
the
Canadian
Standards
Association,
8501
East Pleasant
Valley
Rd, Cleveland
Ohio
44131,
or
The
National
Fire
Protection
Association,
1 Batterymarch
Park, Quincy,
MA 02269.
If after reading
this manual
you have any questions
or do not
understand
any portion
of the instructions,
call the Sears
Service
Center.
Carefully
plan the place where
you are going to put the water
heater.
Correct
combustion,
vent
action,
and vent
pipe
installation
are
very
important
in preventing
death
from
possible
carbon
monoxide
poisoning
and
fires.
See
figure
1.
Examine
the location
to ensure
the water
heater
complies
with the Facts
to Consider
About
the Location
section
in this
manual.
For California
installation
this water
heater
must
be braced,
anchored,
or strapped
to avoid falling
or moving
during
an
earthquake.
See
instructions
for
correct
installation
procedures.
Instructions
may
be obtained
from
your
local
dealer,
wholesaler,
public
utilities
or California
Office
of the
State Architect,
400 P Street,
Sacramento,
CA 95814.
Massachusetts
Code requires
this water heater to be installed
in accordance
with
Massachusetts
248-CMR
2.00:
State
Plumbing
Code and 248-CMR
5.00.
Complies
with
SCAQMD
rule #1121
and districts
having
equivalent
NOx requirements.
RECOVERY
MINIMUM
DIMENSIONS
TANK
TYPE
INPUT
RATE GALS.
VENT PIPE
DIAMETER
IN INCHES (ram)
CAPACITY
OF
RATE
PER HOUR
INCHES
INCHES
HEIGHT TO
MODEL NUMBER IN GALS (LTRS)
GAS
(Btu/hr)
@ 90°F RISE
(ram)
(ram)
JACKET TOP
153.334430
40 (151)
NATURAL
40,000
46.9
3" (76) or 4" (102)
20 I/2" (521)
55 I/2" (1,410)
153.334530
50 (I89)
NATURAL
40,000
45.8
3" (76) or 4" (102)
22" (558)
56 1/2" (1,435)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

334530Hydrosense 153.334430Hydrosense 153,334530

Table of Contents