These guidelines should b eused byaqualified s ervice a gent. Call S ears S ervice at1-800-4-MY-HOME
_(1-800-469-4663)
forassistance. Inform theassociate thatthisisa "Flammable
Vapor I gnition R esistant" Product.
/|'i'i|'tll
WATER L EAKS
LEAKING
T&P VALVE
SMELLY ODORS
PILOT WILL NOT LIGHT
BURNER
WILL NOT STAY LIT
PILOT OUTAGE
NOT ENOUGH
HOT W ATER
WATER TOO HOT
WATER H EATER SOUNDS
SIZZLING
- RUMBLING
SOOTING
VENT GAS ODORS
-1_1,1-1
improperly
sealed,
hot or cold supply
connection,
relief valve, drain valve, or
thermostat
threads.
Leakage from other appliances
or water
lines.
Condensation
of flue products.
Thermal
expansion
in closed water system.
Improperly
seated valve.
High sulfate
or mineral content in water
supply.
Bacteria in water supply.
Gas knob dial not positioned
correctly.
Main gas supply off.
Igniter tip more than 1/8" from pilot hood.
Thermopile
malfunction.
Thermopile
TCO malfunction.
Melted insulation
on ignitor wire or shorting
of ignitor wire.
High ambient
room temperature.
Wire disconnected
from piezo igniter.
Broken electrode
or electrical
wire.
Piezo Igniter generator
fails to operate or
malfunctions.
Thermopile
TCO malfunction.
High ambient
room temperature.
Dirty or clogged
intake Screen.
Flame arrestor
openings
blocked.
Defective
Gas Control.
Dirty pilot burner.
Dirty or clogged
Air Intake Screen.
Thermopile
malfunction.
Thermopile
TCO malfunction.
Defective
Gas Control.
Heater not lit or thermostat
not on.
Thermostat
set too low.
Heater undersized.
Low gas pressure.
incoming
water is unusually
cold.
Leaking
hot water pipes or fixtures.
High temperature
limit switch activated.
Thermostat
set too high.
Condensation
dripping
on burner.
Sediment
or calcium
in bottom or heater
tank.
improper
combustion.
Lack of supply air.
improperly
installed vent piping.
Downdraft.
Poor Combustion.
-|'tl'lll'il
Tighten threaded
connections.
Inspect other appliances
near water
heater.
Refer to CONDENSATION.
Install thermal
expansion
tank (DO NOT
plug T&P valve).
Check relief valve for proper operation
(DO NOT plug T&P valve).
Drain and flush heater thoroughly,
then
refill.
Chlorinate
or aerate water supply.
Refer to LIGHTING
INSTRUCTIONS.
Turn on main gas shutoff valve.
Adjust
ignitor tip.
Replace pilot assembly.
Replace pilot assembly.
Contact
Sears Service
to determine
cause.
Contact
Sears Service
to determine
cause.
Reconnect
wire connector
to piezo igniter.
Replace pilot assembly.
Replace electronic
control module.
Replace pilot assembly.
Contact
Sears Service
to determine
cause.
Clean and reinstall Air Intake Screen.
Contact
Sears Service
to determine
cause.
Replace Gas Control.
Clean pilot assembly.
Clean and reinstall Air Intake Screen.
Replace pilot assembly.
Replace pilot assembly.
Replace Gas Control.
Refer to LIGHTING
INSTRUCTIONS.
Refer to TEMPERATURE
REGULATION.
Reduce hot water use.
Contact
your gas supplier.
Allow more time for your heater to re-heat.
Have plumber
check and repair leaks.
Contact
Sears Service
to determine
cause.
Refer to TEMPERATURE
REGULATION.
Refer to CONDENSATION.
Clean sediment
from tank. Refer to
DRAINING
instructions
in Maintenance
section of manual.
No adjustment
available.
Contact
Sears
Service to determine
cause.
Contact
Sears Service
to determine
cause.