Environmental Specifications - DCA Intertel JP 215 Technical Manual

Rugged thermal printer
Table of Contents

Advertisement

8. Environmental Specifications

(Without transport package)
ENVIRONMENTAL SPECIFICATIONS
1. Temperature
Operating
Humidity
-20 C ~ 30 C
10 ~ 90 % RH
Storage
-30 C ~ 70 C
10 ~ 90 % RH
2. Vibration
Operating
20 ~ 200 Hz
3.0G
3. Shock
Operating
100m/S² 11msec
1⁄2 sinewave
300m/S² 6msec
1⁄2 sinewave
Non-Operating
400m/S² 6msec
1⁄2 sinewave
DCA
Intertel
TEST ITEMS AND TEST CONDITIONS
Low Tempera-
-20°C
ture operating
Host Print: 350cycles (See
Appendix A)
-5°C x 96 hours
Self Print: 1 roll/day (24
Hours) x 4 days(96 Hours)
= 4 rolls
High tempe-
60°C 90% RH x 96 Hours
rature opera-
Self Print : 1 roll/day (24
ting
Hours) x 4 days(96 Hours)
= 4 rolls
Thermal shock
-30°C 1 Hour-70 C 1 Hour,
100 cycles
Low tempera-
ture storage
-30°C 96 Hours
High tempera-
70°C 90% RH x 96 Hours
ture storage
Acceleration: 3.0G
Frequency: 20 ~ 200Hz (Sweep time: 2
min)
Direction: X, Y, Z 3ways
Times 2 Hours/way x 3ways = 6 Hours
Test print
Note:
Printing may be distributed
during the vibration but must be readable
Direction 6 ways
Times 1/way x 6ways=0
times
Note: Function may be
disturbed during the
shock, but shall remain
undisturbed after the
shock
Direction 6 ways
Times 1/way x 6 ways=6
times
16
DCA
Intertel
ENVIRONMENTAL SPECIFICATIONS
4. life (without
5 years (7000m)
thermal head
5. Electrostatic
6kv Discharge
Discharge
150pF. 150
10kv Discharge
150pF.150
6. Radiation
Frequency
Noise
50MHz ~ 1000MHz
Peak
Max. –95dBm
7. Ambient Field
Frequency
Susceptibility
80. 160. 200. 450.
81. 900 MHz
Electromagnetic
Field Strength : 100
V/M
8. Voltage
Operating Voltage
Variatons
10 ~ 16 V
DCA
Intertel
TEST ITEMS AND TEST CONDITIONS
Life Test
Normal Temperature
and Humidity Self Print
No malfunction
Host Print with Personal
Computer (See Appen-
Only software
dix C)
errors recog-
nizable and
recoverable by
normal softwa-
re errors han-
ding procedures
may occur
Check the radiation on power cable and
data cable (See Appendix B)
An electromagnetic field generated from
transmitting antenna placed at a distance
of 1 meter from the printer. May not cau-
se malfunction to the printer (See Appen-
dix D)
Voltage Variation
Test Print
Test
17