General information

Unit installation
Read this instruction manual thoroughly
before installing the unit and keep it for
further consultation even after installation.
• This unit complies with the following
directives:
- low-voltage 73/23/CEE;
- electromagnetic compatibility 89/336/CEE;
- PED Pressure Equipment 97/23/CE;
- energy labelling 2002/31/CE.
• For safety reasons, installers are required to
read the general information carefully.
• Follow all the instructions below to ensure
safety.
• Inspect the unit for damage due to improper
transport. In case of damage, file an
immediate claim with the shipping company.
• Do not install or use damaged equipment.
• To prevent fire, explosion or injury, do not
operate the unit near dangerous substances
or close to naked light equipment.
• Ensure that national safety code
requirements have been followed for the
main supply circuit. Follow all current
national safety code requirements for the
installation.
• Make sure a connected ground wire is in
place.
• Check that voltage and frequency of the
mains power supply are those required for
the unit to be installed; the available power
must be adequate to operate any other
appliances connected to the same line.
• The manufacturer declines any liability from
damage resulting from modifications in the
unit or errors in the electrical or hydraulic
connections.
Failure to observe the installation
instructions, or use of the unit under
conditions other than those indicated in the

Correct use

GB - 2
table "Operating limits" of the unit owner's
manual, will immediately invalidate the unit
warranty.
• It is recommended to install a circuit breaker
or a 16 A safety fuse upstream of the supply
outlet.
Unit operation
• In order to avoid electric shock, fire or injury,
stop the unit in case of abnormal events
(such as smell of burning) and call Carrier
Service for further instructions.
• Do not place containers filled with liquids or
other objects onto the unit.
Maintenance
WARNING:
disconnect the mains power supply prior
to any maintenance operations or prior to
handling any internal parts of the unit.
• A routine maintenance should be carried out
on the unit to check the correct operation of
the electric connections and protection
devices.
• A damaged power cord of units equipped
with quick-connection couplings of the Y-type
must be replaced by the manufacturer or its
after-sales service.
• Maintenance operations must be carried out
by specially trained personnel.
• Do not attempt to repair, move, modify the
unit on your own. To avoid electric shock or
fire make sure these operations are carried
out by qualified personnel only.
• Contact the qualified service if one of the
following events takes place:
- hot or damaged power supply cable;
- unusual noise during operation;
- frequent operation of the protection devices;
- unusual smell (such as smell of burning).
The air conditioner models
51AKB010 consist of two
units connected by a flexible
tube of 1.8 metre length.
Models 51AKC013 sare
provided with a flexible tube
of 3.6 metre length and
quick coupling connections
that allow the units to be
disconnected up to a
maximum of six times
without impairing air
conditioning performance.
This operation must
always be carried out by
qualified and authorized
personnel.
IMPORTANT
At first start-up of the unit proceed
as follows:
• take out the water tank at the rear
of the air conditioner
• remove the adhesive tape strip
• replace the tank correctly in its
position
If the above procedure is not followed,
the unit will not operate and indicate a
fault.
Choosing the installation site
• Choose an area free from obstructions which
may cause irregular air distribution and/or return.
• Choose a position that allows for the clearances
required (see "Correct use" section).
• Look for a position in the room which
assures the best possible air distribution.
Positions to avoid:
• Exposed to direct sun.
• Too close to heat sources.
• On humid walls or positions with water
hazard, e.g. laundry premises.
• Exposure to oil vapours (e.g. kitchens,
workshops).
• Where curtains or furniture may obstruct free
air circulation.
Unit disposal:
• At the end of its life, the air conditioner must
be delivered to a special collection centre or
to the dealer for the refrigerant disposal.
• All of the manufacturing and packaging
materials used for this unit are compatible
with the environment and can be recycled.
• Dispose of the packaging material in
accordance with local requirements.
SPLIT unit performance:
The unit is designed to operate within the following
temperature limits according to the standards:
Cooling: (EN14511:2004)
Indoor temperature
Max. 32°C d.b.* / 23°C w.b.*
Min. 21°C d.b.* / 15°C w.b.*
Outdoor temperature:
Max. 46°C - Min. 21°C
Dehumidification:
Max 32°C d.b.* / 24°C w.b.*
Min. 18°C d.b.* / 14°C w.b.*
* d.b. - dry bulb temperature -
* w.b. - wet bulb temperature
The elegant portable indoor unit may be
positioned conveniently in the room to be air conditioned.
The compact, light weight
outdoor unit is placed
outdoors.
The outdoor unit
may be hung on
the back of the
indoor unit with the
flexible tube neatly
coiled, but never
kinked, to allow air
conditioner to be
moved from room
to room. It is
recommended to
move the unit
holding the front
panel as illustrated.