Perlick HP24FS Operation & Installation Manual page 25

Signature series hp24- and hp48-inch models
Hide thumbs Also See for HP24FS:
Table of Contents

Advertisement

Problem: Controller display is flashing "HA"
The internal compartment temperature has exceeded the high temperature alarm preset value for over 30 minutes.
Check to ensure door is closed
Check door gasket seal
Has warm product been placed in the cabinet?
Is the condenser clean?
In the louvered toe plate obstructed?
Has the surrounding ambient temperature changed dramatically?
Is the interior light ON?
Problem: Controller display is flashing "LA"
The internal compartment temperature has exceeded the low temperature alarm preset value for over 30 minutes
Check to ensure door is closed
Check for gasket seal
Has the surrounding ambiant temperature changed dramatically?
Problem: Controller display is flashing "EE"
The controller has a data or memory failure
Problem: The refrigerated cabinet isn't running
Is there electrical power to the unit?
Is your home circuit breaker or fuse on?
Is your ON/OFF key pad on?
Is your condenser area clean?
Problem: The refrigerated compartment is warmer than usual
Is your control set properly?
Is the light staying on?
Is your condenser area clean and free of obstructions?
Has the door been open for a long time or more frequent door openings occured?
Are the internal louvers and fan guard openings obstructed?
Has warm product been placed in the cabinet?
Problem: The refrigeration system runs for long periods of time
Is the condenser area clean and free of obstructions?
Have the doors been open for a long time or more frequent door openings occured?
Has warm product been placed in the cabinet?
On hot days and in warm room temperatures the system will run long
Problem: Condensation forms inside the refrigerated compartments
This is normal during high humidity and frequent door openings
Are the doors closing and sealing properly?
Problem: Condensation forms on the outside of the unit
During periods of high humidity some condensation might appear on outside surfaces. The condensation will disappear when the
humidity drops. Meanwhile, be sure doors are closing and sealing properly. If condensation persists, contact your Perlick Factory
Authorized Service Center.
You need product information:
Contact your selling dealer
Inquire via the web at www.perlick.com
Call (800) 558-5592 for factory assistance on planning, installation or product information.
Write to: Perlick Corporation, Customer Service Department, 8300 West Good Hope Road, Milwaukee, WI 53223
E-mail us at warrantyserv@perlick.com
Operation & Installation Manual
Signature Series (HP24 and HP48 models)
25