Diagnostic Display - Kenmore Elite 153.331010 Use & Care Manual

Hybrid gas water heater
Hide thumbs Also See for Elite 153.331010:
Table of Contents

Advertisement

DIAGNOSTIC DISPLAY

By simultaneously pressing the "Mode" and "down arrow" buttons for 3 seconds the unit will allow access to the diagnostic
mode.
In diagnostic mode, using the up/down arrow allows for cycling between diagnostic codes. The numeric display will
show the diagnostic code for 1 second, followed by the actual measurement displayed for 3 seconds. For example, H01
- 105 represents the diagnostic code of "H01" and the value of "105" is the inlet water temperature measurement. The
display will continue to show the diagnostic code and the measurement value unless the up or down arrows are pressed
to switch to the next item (see Table 3). If no buttons are pressed for 30 seconds the unit will revert back to operation
mode where the set-point temperature is displayed.
Diagnostic
Description
Code
H01
Inlet Water
Temperature
H02
Heat engine outlet
water temperature
H03
Storage tank
temperature
H04
Heat engine water
fl ow rate
H05
Fan Speed
H06
Fan Current
H07
Proportional Valve
Current
H08
Total Heating
Time
H09
Total Cycles
H10
Heat Engine
Rated Output
H11
Current Error
Code (See Fault
Code Table)
H12 – H20
Error Code
History, From the
Most Recent to
the Least Recent
(See Fault Code
Table)
H21
Software
Release Number
(CWHCB)
H22
Software Release
Number (UIM)
H23
Confi guration File
Number
Code and
Measurement
Units
Display
(Example of)
Format
H01 – xxx
ºC or ºF
H02 – xxx
ºC or ºF
H03 – xxx
ºC or ºF
H04 – xxx
litres/minute
H05 - __x – xxx
rpm
H06 - __x – xxx
mA
H07 – xxx
mA
H08 – xxx – xxx
hours
H09 – xxx – xxx
heating cycles
H10 – xxx
KBtu/hour
H11 – xxx
N/A
Hxx – xxx
N/A
H21 – xxx – xxx
N/A
H22 – xxx – xxx
N/A
H23 – xxx – xxx
N/A
TABLE 3
Displayed
characters
Meaning
(Example of)
041 or 105
41ºC or 105ºF
041 or 105
41ºC or 105ºF
041 or 105
41ºC or 105ºF
056
5.6 litres/minute
(1.48 Gallons/
minute)
006_511
6511 rpm
001_456
1456 mA
(1.456A)
178
178 mA
001_234
1234 hours
(51.41 days)
000_459
459 heating
cycles
100
100 KBtu/hour
E00
Proper operation
- No error
E28
Ignition failure
002_025
Software release
number 2.25
002_009
Software release
number 2.09
000_006
Confi guration fi le
number 6
Remarks
ºC LED or ºF
LED turned ON
ºC LED or ºF
LED turned ON
ºC LED or ºF
LED turned ON
1 litre =
0.264 Gallons
1 gallon =
3.78 litres
rpm=rotations
per minute
mA=milliampers
mA=milliampers
The most
recent error
corresponds
to H12 and the
least recent to
H20
For the main
controller board
For the display
board
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite 153.331000Elite 153.331000 ha

Table of Contents