Please note when you open the carton carefully check the unit and make sure there
are no damages. If you have any problems with the unit, with how the various
functions work or with hidden damages or missing parts, please call: 1-800-459-
4409 (EST) for customer service. NOTE: DO NOT RETURN UNIT TO THE STORE
BEFORE CALLING THE TOLL FREE NUMBER. Do not dispose of your packaging
cartons until you are completely satisfied with your new fireplace heater. Read
all instructions thoroughly before operating your new Electric Fireplace.
NOTE: Light bulbs may become loose during shipping. If the flame effect is dim or
does not work, please check that light bulb or bulbs are finger tight in socket. See
instructions for replacing bulb or bulbs.
NOTE: The electric fireplace heater may emit a slight harmless odor when first turned
on. This is caused by activating the internal heater components for the first time and
should not occur again.

ASSEMBLY INSTRUCTIONS

partS liSt

Z. WALL ANCHOR SAFETY CABLE
Wall Anchor ......................................................................................................................... 1
Screw for wall anchor ....................................................................................................... 1
Screw for mantel ............................................................................................................... 1
Safety cable ........................................................................................................................ 1
CAUTION: Carefully move the assembled unit to the desired location. The Fireplace
Mantel should not be positioned in an area exposed to direct sunlight.
Wall aNcHOr SaFEtY caBlE
The use of WALL ANCHOR SAFETY CABLE is highly recommended in order to reduce
the risk of the fireplace being tipped over accidentally. WARNING: This CABLE may re-
duce possible risk of injury if the fireplace is improperly handled, but is not a substitute
for proper adult supervision. Children should not be left unattended near any heater.
1. Drill a 5/16" (8mm) hole in the wall. Insert the PLASTIC WALL ANCHOR into the
hole and gently tap until the flange on the anchor is against the wall surface.
2. Position the back edge of the mantle close to the wall.
fig. A
3. Attach the SAFETY CABLE to the mantle using the SCREW FOR MANTLE. See fig. A
4. Use the SCREW FOR WALL to attach the other end of SAFETY CABLE to the wall.
5. Make sure all screws are tight. OPERATION

OPERATION

After reading complete instructions, confirm all controls on fireplace are in the OFF
position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach,
you may use an extension cord rated for a minimum of 1875 WATTS. Once the
fireplace insert has been properly connected to a grounded electrical outlet, it is ready
to operate.
OpEratiON BY tHE cONtrOl paNEl
The controls are located behind the grill below the front glass and can be accessed by
pulling the grill from the top, forward and down.
ON/OFF: Press this button for main power and flame effect. The indicator light will
turn on. See below for other control switches.
750W: For low heat function - Press this switch while the ON/OFF switch is in the on
position for low heat. The indicator light will turn on.
1500W: For high heat function - Press this switch while the ON/OFF switch and the
750W switch are in the on position for high heat. The indicator light will turn on.
Temperature Control: To adjust the temperature to your individual requirements,
turn the temperature control dial to the right (clockwise) to increase the desired tem-
perature and to the left for lower temperature. This temperature control dial can only
be used while the ON/OFF switch and 750W &1500W switches are in the ON position.
When the heater reaches to the desired temperature, the heater and 750W/1500W
indicator light will turn off but the fan still keeps working with air flow. Adjust this
knob to restart the heater.
Dimmer Control Knob: Turn the dimmer dial clockwise or counter clockwise to get
the desired flame intensity. The dimmer switch can only be used when the ON/OFF
switch is in the on position.
Note: When the ON/OFF switch is turned off, all other heater functions will stop even
though the switches may be in the on position.
OPERATION BY THE REMOTE CONTROL
Plug in your electric fireplace and it will beep once, this means you have power and
your remote is ready to operate your electric fireplace.
ON/OFF: Press this button for main power function. The unit will beep and the indica-
tor light will be on. Pressing again will stop the main power function.
Once the heater is switched off, the indicator light will flash and the unit will keep
working with air flow for 5 more seconds.
FLAME/LOG: Press this button once for flame effect. The unit will be beep and the
indicator light will be on. The bulbs for flame effect & log-set will be on. Pressing but-
ton again will stop the light function.
750W: Press this button for low heat level. The unit will beep, the pilot light and
indicator light will be on. The fireplace heater will give low heat level. Pressing once
again will stop the low heat level function.
2