Water Connection; Water Piping; Check Valve Installation - Jandy DP3000 Installation And Operation Manual

Oil-fired pool and spa heater
Table of Contents

Advertisement

ONE-PIPE SYSTEM
TWO-PIPE SYSTEM
Figure 7. One-Pipe and Two-Pipe Systems.
Table 3. Fuel Line Sizes.
Lift From
Bottom of
Total Tubing
Storage Tank
Length Allowed
to Fuel Pump
Using 3/8" dia.
on Heater
Pipe
0 ft. (0.0m)
68 ft. (20.7m)
2 ft. (0.6m)
63 ft. (1 9.2m)
4 ft. (1.2m)
58 ft. (17.7m)
6 ft. (1.8m)
53 ft. (16.2 m)
8 ft. (2.4m)
48 ft. (14.6m)
10 ft. (3.0m)
42 ft. (12.8m)
12 ft. (3.7m)
37 ft. (11.3m)
14 ft. (4.3m)
32 ft. ( 9.8m)
16 ft. (4.9m)
27 ft. ( 8.3m)
18 ft. (5.5m)
22 ft. ( 6.7m)
Figure 8. Oil Filter Installation.
SECTION 5.
Water Connections

5.1 Water Piping

Total Tubing
Length Allowed

5.2 Check Valve Installation

Using 1/2" dia.
Pipe
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
100 ft. (30.5m)
88 ft. (26.8m)