B−SureLight Board 100870
Dip Switch Settings and On Board Links (See figure 5)
Thermostat
DIP Switch 1
1Heat / 1 Cool
ON
NOTE − Use DIP
switch 2 to set
second−stage
heat ON delay.
OFF−10 minutes.
ON−15 minutes.
1 Heat / 2 Cool
ON
NOTE − Use DIP
switch 2 to set
second−stage
heat ON delay.
OFF−10 minutes.
ON−15 minutes.
1 Heat / 2 Cool
ON
with t'stat with
humidity control
NOTE − Use DIP
switch 2 to set
second−stage
heat ON delay.
OFF−10 minutes.
ON−15 minutes.
TABLE 48
Field Wiring Applications (Continued)
W915
W914 Dehu-
Two−Stage
midification
Cooling
or Harmony
III
Intact
Intact
Cut
Intact
Cut
Cut
Page 93
W951
Wiring Connections
Heat Pumps
Intact
S1
T'STAT
Intact
S1
T'STAT
Intact
S1
T'STAT
CONTROL
OUTDOOR
TERM. STRIP
UNIT
CONTROL
OUTDOOR
TERM. STRIP
UNIT
CONTROL
OUTDOOR
TERM. STRIP
UNIT