NOTICE: This heater is intended for use as supple-
mental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system's circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
WARNING: A qualified service person must install
fireplace. Follow all local codes.
WARNING: Never install the heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing or other flam-
mable objects are less than 42" from the front, top
or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall cov-
erings or operating heater where impurities (such as,
but not limited to, tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene lamps, etc.) in the air
exist, may discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to the air. Although this
is beneficial, installing heater in rooms without enough ventilation
air may cause mildew to form from too much moisture. See Air for
Combustion and Ventilation, page 5.
CHECK GAS TYPE
Use only the correct type of gas (natural or propane/LP). If your gas
supply is not the correct gas type, do not install heater. Call dealer
where you bought heater for proper type heater.
WARNING: This appliance is equipped for either
natural gas or propane/LP gas but not both. Gas type
is indicated on the rating plate. Field conversion is
not permitted.
127113-01A

INSTALLATION

CLEARANCES TO COMBUSTIBLES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling
and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding
unit designed to set directly on the floor. IMPORTANT: You must
maintain minimum wall and ceiling clearances during installation.
The minimum clearances are shown in Figure 4. Measure from
outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from outermost point of stove top to any combustible
side wall should not be less than 12".
B. Clearances from outermost point of stove top to any combustible
back wall should not be less than 6" (includes corner installations).
C. Clearances from the stove top to the ceiling should not be less
than 48".
Side Wall
Corner
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May
www.Superiorfireplaces.US.com
Ceiling
48"
Minimum
12"
Side
Minimum
Wall
Back Wall
6 "
Minimum
12 "
Minimum
Top View
Front of
Stove Unit
Wall
6 "
Minimum
Wall
6 "
Minimum
Minimum
Front of
Stove Unit
Vary Depending on Model)
Front
View
12"
Minimum
Side
Wall
12 "
Minimum
Side Wall
Ceiling
Side
View
48"
6"
Back
Minimum
Wall
Floor
7