Preface Thanks for using this USB3.0 HD Video Conferencing Camera. This manual introduces the function, installation and operation of the HD camera. Prior to installation and usage, please read the manual thoroughly. Precautions This product can only be used in the specified conditions in order to avoid any damage to the camera: n...
Note l Electric Safety Installation and operation must accord with electric safety standard. l Caution to transport Avoid stress, vibration and soakage in transport, storage and installation. l Polarity of power supply The power supply of the product is +12V, the max electrical current is 2A .Polarity of the power supply plug drawing as follows.
Quick Start Step1. Please check connections are correct before starting Step2. Setting switches Set both of the switch1 and switch2 to "OFF'. That is "Normal Working Mode". SW-1 SW-2 Modes Normal Working Mode...
Page 6
Step3. Setting of the system select switch The option of video format: VIDEO SYSTEM 1080i60 1080i50 720p60 720p50 576i 1080p30 480i 1080p25 CAUTION: a. After changing the switch, you need to restart the camera to take effect. Step4. Press the Switch ON/OFF button on the rear of the camera, the power lamp light. Step5.
RESTORE DEFAULT Restore Change Value [Home] OK [Menu] Back Features 1. Support USB3.0 transmission, the highest rate up to 5Gbps, ensure real-time lossless HD data transmission. 2. Support HD USB3.0,HD-SDI(optional),Network stream, three-stream simultaneous output, compatible with CVBS. 3. Adopt Panasonic's 1/3 inch, 2.12 million pixels high quality HD CMOS sensor, which can realize maximum 1920 x 1080 high resolution image with high quality, maximum output frame rate reach 30 frames per second.
Product Specification Model 20X-USB Name PTZ Optics USB3.0 Type HD Color Video Camera Camera 1080i/60,1080i/50, 1080p/30, Sub stream Video System 1080p/25, 720p/60, 720p/50, 640x360,320x180 resolution NTSC, PAL 128K,256K,384K,512K,768K,1024 1/3", CMOS, Total Pixel: 2.2M, K,1536K,2048K,3072K,4096K, Sensor Rate Effective Pixel: 2.12M 5120K,6144K,8192K Optional,...
Page 9
1xRS-232 IN: 8pin Min DIN, Max Horizontal Rotation ±170° Distance: 30m, Protocol: VISCA/ Range Pelco-D/Pelco-P Control Input/Output 1xRS-485: 2pin phoenix port, Vertical Rotation -30° ~ +90° Max Distance: 1500m, Protocol: Range VISCA/Pelco-D/Pelco-P JEITA type (DC IN 12V) Pan Speed Range 1.7°...
Main Unit 1. Audio LINE IN Interface 7. RS232 IN jack 2. Audio LINE OUT Interface 8. RS232 OUT jack 3. CVBS Interface 9. Network 4. Dip switches 10. USB3.0 5. System select switch 11. DC 12V jack 6. RS485 jack 12.
IR Remote Controller Explanation 0. Standby Button Press this button to enter standby mode. Press it again to enter normal mode. (Note: Power consumption standby mode approximately half of the normal mode) 1. Position Buttons To set preset or call preset 2.
Page 12
Press [AUTO] adjust the focuses on the center of the object automatically. To adjust the focus manually, press the [MANUAL] button, and adjust it with [Focus+] (Focus on far object) and [Focus-] (Focus on near object) 6. Camera Select Buttons Press the button corresponding to the camera you want to operate with the remote controller.
USE IR Remote Controller When the camera is working, you can use remote Press and hold the up/down/left/right button, the controller to perform panning, tilting, zooming and camera will keep rotating from slow to fast, until it run to focusing, store and call back preset positions. the mechanical limit;...
Page 14
3. Focus Control Focus Far: Press [FOCUS+] button (NOTE: Effective only in manual focus mode) Focus Near: Press [FOCUS-] button (NOTE: Effective only in manual focus mode) Press and hold the button, the action of focus continues 1. To store a preset position: The users should press and stops as soon as the button is released.
Page 15
7. Camera Selection Press the button corresponding to the camera you want to operate. Press any of the numeric buttons 0-9 directly to recall stored preset positions and settings. 8. Camera IR Address Set Note: No action is executed if a relative preset position is not stored.
RS-232 Interface Camera Windows DB-9 1.DTR 1.CD 2.DSR 2.RXD 3.TXD 3.TXD 4.GND 4.DTR 5.RXD 5.GND 6.GND 6.DSR 7.IR OUT 7.RTS 8.NC 8.CTS 9.RI Camera Mini DIN Function 1.DTR 1.DTR 2.DSR 2.DSR 3.TXD 3.TXD 4.GND 4.GND 5.RXD 5.RXD 6.GND 6.GND IR OUT 7.IR OUT 7.NC 8.NC...
Serial Communication Control In default working mode, the camera is able to connect to a VISCA controller with RS232C serial interface. RS232
C ommunication
C ontrol
Ø The camera can be controlled via RS232 ,the parameters of RS232C are as follows: Baud rate: 2400/4800/9600 bit/s.
Page 18
The camera can be controlled via RS485, Half-duplex mode, supports VISCA or Pelco-D or Pelco-P protocol, supports the following configurations: Baud rate: 2400/4800/9600 bit/s. Start bit: 1 bit. Data bit: 8 bits. Stop bit: 1bit. Parity bit: none. Pan-Tilt will rotate to the maximum position of top right after the camera started, then it return to the center, the process of initialization is finished.
Page 19
VISCA Command List Part 1 Camera-Issued Messages Ack/Completion Message Command Function Command Packet Comments z0 4y FF Return when the command is accepted. ACK/Comletion (y: Socket No.) Messages z0 5y FF Return when the command has been Completion (y: Socket No.) executed.
Page 20
Returned when a command canot be z0 6y 41 FF executed due to current conditions.For Command Not Executable (y: Execution command Socket example, when commands controlling the No. Inquiry command: 0) focus manually are received during auto focus. Part 2 Camera Control Command Command Function Command Packet...
Page 26
CAM_RegisterValueI mm: Register No. (00 to FF) pp: Register 8x 09 04 24 mm FF y0 50 0p 0p ff Value (00 to FF) p: Color Gain setting 0h (60%) to Eh CAM_ColorGainInq 8x 09 04 49 FF y0 50 00 00 00 0p FF (200%) CAM_IDInq 8x 09 04 22 FF...
Page 27
y0 50 01 FF C Type CAM_TypeInq 8x 09 00 03 FF y0 50 02 FF M Type y0 50 03 FF S Type Version dater: Big Version Numberss: CAM_DateInq 8x 09 00 04 FF y0 50 0r ss uu uu vv ww 0D FF Little Version Numberuuuu: Yearvv: Monthww: Day y0 50 00 FF...
Menu Setting 1. MENU EXPOSURE Press [MENU] button to display the main menu on Mode Auto the normal screen, using arrow button to move the cursor ExpCompMode to the item to be set. Press the [HOME] button to enter the Backlight corresponding sub-menu.
Page 32
Bright: Intensity control, Optional items: 00~17. COLOR (Effective only in Bright mode) WB Mode Auto Anti-Flicker Flicker: Anti-flicker. Optional RG Tuning items: Off, 50Hz, 60Hz (Effective only in Auto, BG Tuning Bright mode) Saturation 100% Iris: Aperture value. Optional items: F1.8, F2.0,F2.4,F2.8,F3.4,F4.0,F4.8,F5.6,F6.8,F8.0,F9.6,F11.0, IR Filter Close(Effective only in Manual, AAE mode)...
AWB sens: The white balance sensitivity, Flip-V: Image Flip Vertical. Optional items: On,Off Optional items: Normal, High, Low. B&W-Mode: Image color. Optional items: On, Style: Optional items: Style1, Style2, Style3. Gamma: Optional items: Default,0.45,0.5,0.56, 0.63 4. IMAGE Move the cursor to the Image item in the main menu 5.
Page 34
main menu press [home] button, NOISE SETUP REDUCTION menu appears, as shown in the Language following figure. Protocol VISCA NOISE REDUCTION V_Address NR2D-Level 3 V_AddrFix NR3D-Level 3 Net Mode Serial D-HotPixel Baudrate 9600 Select Item Change Value [Menu] Back Select Item Language: menu language, Optional items: EN, Change Value Chinese...
Page 35
Baudrate: Serial port baud rate. Optional items: 2400, parameter restore default, Include IR Remote address and 4800, 9600 VISICA Address Save: Save Options. Optional items: Yes, No 8. RESTORE DEFAULT Move the cursor to the Restore Default item in the main menu and press [home] button, RESTORE DEFAULT menu appears, as shown in the following figure.
Equipment Setup and internet connection 1. Operating Environment Operating System: Windows 2000/2003/XP/vista/7 Network Protocol: TCP/IP Client PC: P4/128MRAM/40GHD/ support scaled graphics card, support DirectX8.0 or more advanced version. 2. Equipment Installation 1) Connect internet camera to your internet or to your PC directly via internet cable. 2) Turn on DC12V power.
Page 37
Picture 1.2 Connect by router /interchanger IP camera visited/ controlled by LAN Setup IP address 1.1 Connect IP Camera to internet (or PC), then turn on the power on IP Camera, shown as above. IP address can be searched via update software(software upgrading tool,named upgrade_En.exe in small CD in package). shown as below: Run upgrade_En.exe (UPGRADE v1.8) by CD-Rom, click [Search].The software will show the current LAN camera's IP address, subnet mask number, network gateway number and camera MAC serial number etc, shown as below: If IPC IP address and PC IP address not in the same internet segment, upgrade_En.exe can modify IP address, subnet...
Page 39
Enter new IP in "IP" bar, subnet mask in "Mask" bar, Gateway,First DNS, MAC address,and click “Set”. Shown as above.(For example: if your PC IP is 192.168.1.88, then camera IP must be 192.168.1.xx, the first, second, third number must keep the same) NOTE IP camera default IP address"192.168.100.88", user "admin", password "admin".
Page 40
2.2 Input login name and password, click "confirm", then pop up below window,language select button on the left bottom:...
Page 41
! NOTE If user first time use this camera by internet (only for new user), must install a player software (VLC). Please go to Then Install VLC (player software), http://4dx.pc6.com/xy/vlcplayer.zip,pop out the download window, click“Save”. After installation,login again,will show as above: IP Camera accessed/controlled by WAN (internet) 1.
Dynamic DNS visit camera 1.1 Camera accessed by dynamic DNS Set domain name to camera, setup the parameter, then dynamic DNS can access camera. Access link:http://hostname :port number For example, setup host computer name: youdomain.f3322.org, camera port number: 554, Access link should be: http://youdomain.3322.org:554 !...
Page 43
1.2 Input URL address: rtsp://ip: port number/1 (Main stream); rtsp://ip: port number/2(sub stream)(When RTSP port number default value is 554,then can be omitted as rtsp://ip/1 or rtsp://ip/2)
IP Camera parameter setup Homepage introduction 1.1 Menu All pages include 2 menu bars: Real time monitoring: displaying video image Parameter setup: with function buttons 1.2 Video viewing window Video viewing window must be same as video resolution, the bigger the resolution is, the bigger the playing area is. Double click viewing window, will show full-screen, double click again, will return to initialized size.
Page 45
1) PTZ direction control box: Up, down, left, right, home oblique button as above 2) Rate: Vertical speed can be chosen as 1 ~ 24, horizontal direction at the rate of 1 ~ 20. select corresponding speed and click direction button to realize PTZ speed up or speed down. 3) Zoom In/Zoom out: for zooming in or zooming out, Focus In/ Focus Out: Focusing on distant objects or Focusing on close objects.
Page 46
Media 1.1 Video Setup,please click "Video" Video format Support 50HZ(PAL)and 60HZ(NTSC),and Dial priority three formats. Video Coding Support baseline and mainprofile format Resolution...
Page 47
Main bit flow support 1920x1080,1280x720,minor bit flow support 640x360,320x180,the bigger resolution is, the clearer the image will be, more network bandwidth will be taken. Bit Rate User can assign bit flow/stream, normally speaking, the bigger bit flow is, the clearer the image will be. The bit allocation must combine with network bandwidth, when the network bandwidth is too narrow and the allocated bit flow is too big, will cause video signal flow not to be transmitted normally, the video effect will be worse.
Page 48
Brightness Image bright 0~100, slider control, on the right shows the corresponding numerical. Default 43. Saturation Saturation 0~100, slider control, on the right shows the corresponding numerical. Default 50. Contrast Contrast0~100, slider control, on the right shows the corresponding numerical. Default 57. Sharpness Sharpness0~100, slider control, on the right shows the corresponding numerical.
Page 49
Adjusted the wide-angle lens image distortion occurs, controllable range 0 ~ 100, right shows the corresponding numerical. Default 0. Flip & Mirror Tick Flip to realize image upside down, tick mirror to realize image around the mirror. Default not tick. Button Adjusting the parameters, press "apply"...
Page 50
Input VolL The volume of the left channel Input VolR The volume of the right channel Button Press "apply" button to save parameters, press "cancel" button to cancel parameter System Setting,please click “System” Work Mode Work Mode RTSP Reboot Click the "Reboot" button, system restart. User and password The user can modify the password (letters and Numbers only) Apply / Cancel...
Page 51
Lan Settings
Default the IP address is 192.168.100.88, The MAC address can be modified. Port Settings
IP address identifies the network device, the device can run multiple web applications, each network program using network port to transmit data, so data transmission to be carried out between the port and port. Port setting is to set up WEB SERVER program using which port to transmit.
Page 52
Network camera support RTSP protocol, use the VLC tools broadcast. TCP Port
Support TCP protocol, default port: 5678. Apply / Cancel
Modify network parameters then press "Apply" button to modify network parameters, press "Cancel" button to cancel network parameters. Device Information,please click “information”...
Network Control 1. View from Web browser (better in IE) l To view from web browser, firstly need to check camera IP address. There are 2 methods to check: Method 1: press * and # and 4 on remote controller one by one, the camera IP address will be shown on screen.
Page 54
Method 2: Open “upgrade_En.exe”, change IP and click “Set”...
Page 55
Once IP changed, need to restart the camera. 2 methods to restart as below: Method 1: Turn off and turn on manually to restart camera Method 2: On web page, find “System” and click “Apply” (when under remote controlling environment, better use this method)
Page 56
PTZ ON IP NETWORK This model currently supports various PTZ control methods, including RS232, RS485, IR remote control, HTTP CGI, and TCP protocol. The following is the detailed description about HTTP CGI and TCP Protocol control methods. 1. TCP Protocol Method V51N implements TCP server inside, there is a port configurated by Web for receiving the connection from TCP client,the TCP port number is 5678.
Page 58
http://[Camera IP]/cgi-bin/ptzctrl.cgi?ptzcmd&[action]&[position number] More descriptions: [Camera IP]: This camera IP address; [action] including: posset, poscall; [position number]: 0-89,100-254. USB Control Connect USB cable from camera to computer (must with USB3.0 port) Install the software in the small CD in the package (amcap.exe) ,and click to open.
Maintenance and Troubleshooting Camera Maintains l If camera will not be used for a long time, please turn off the power switch, disconnect AC power cord of AC adaptor to the outlet. l Use soft cloth or tissue to clean the camera cover. l...
3. Check IR address of the Remote Commander is set correctly. l Serial communication cannot control the camera 1. Check the camera working mode. 2. Check control cable is connected correctly. Copyright Notice All contents of this manual, whose copyright belongs to our Company. Cannot be cloned, copied or translated without the permission of the company.