OPERATING INSTRUCTIONS
To Start up a Hot Stove
If the stove is warm at re-start, the On/Off button must be pressed down and held for 2
seconds or more until the Heat Level light is lit.
When first starting a new pellet stove, or when you completely empty the hopper of
pellets, you can press and hold the AUGER button to get the pellets into the burn pot
quicker. See AUGER button description on page 10.
The convection air flow will change in accordance with the heat setting. Convection air
flow is at maximum when the heat setting is at maximum. Air flow will be at a minimum
when the heat setting is at a minimum. If the user wishes to turn the convection fan on
maximum, at any heat setting, they may do so by pressing the FAN button.
If the flame goes out, use the AUGER TRIM button to make adjustments. See the
AUGER TRIM button description on page 11.
To Shutdown Stove
Turn off the unit by pressing the On/Off button. The stove will enter the shutdown cycle
where the pellets will stop feeding to allow the fuel in the burn pot to be used up. The
exhaust blower and convection fan will continue to operate until the flames are out and
the unit has cooled down. Once this has been accomplished the stove will shut down
completely.
In the T-STAT mode turning the thermostat all the way down can also be used to turn off
the stove.
DO NOT TURN OFF THE UNIT BY DISCONNECTING THE ELECTRICAL
POWER TO THE UNIT. THIS WILL CAUSE THE UNIT TO MISS THE
PROPER SHUTDOWN CYCLE, CAUSING THE RELEASE OF SMOKE INTO
THE HOUSE AND OVERHEATING OF THE STOVE.