Alarms - Videoswitch Vi400 User Manual

Vi400 series; vi600 series
Hide thumbs Also See for Vi400:
Table of Contents

Advertisement

9.4

Alarms

9.4.1 Alarm Inputs
9.4.1.1
Alarm Polarities
Select whether alarm inputs are normally open or normally closed.
9.4.1.2
Camera Mapping
Specify which camera each alarm input will "pull-up" when activated. This is also the camera
that the preset mapping applies to (see below)
9.4.1.3
Preset Mapping
If you want a dome or pan and tilt camera to go to a preset on alarm, specify the preset here
for each alarm input. Set to "None" if no preset is to be invoked.
9.4.1.4
Alarm Timers
9.4.1.4.1
Weekday Alarm Times
Specify the times during which alarms will be detected for Monday, Tuesday, Wednesday,
Thursday and Friday using the LEFT, RIGHT, UP and DOWN keys.
9.4.1.4.2
Weekend Alarm Times
Specify the times during which alarms will be detected for Saturday and Sunday using the
LEFT, RIGHT, UP and DOWN keys.
9.4.1.5
Enable All Day
Some cameras may have their alarms enabled all day, irrespective of the above timers.
9.4.2 Activity Detection
9.4.2.1
Activity Zones
Activity detection zones may be set for each camera.
Use the UP, DOWN, LEFT and RIGHT keys to move the screen cursor around and the
OK key to toggle between setting zones and clearing zones.
Where zones are set, activity will be detected.
Use the number keys to enter the sensitivity and number of pixels that have to be active to
trigger an alarm. For example enter 62 to set the sensitivity to 6 and the pixel count to 2.
The higher sensitivity setting, the more sensitive the activity detection is.
The higher the pixel count, the less sensitive the activity detection will be to false triggering.
32
Digital Recorder

Advertisement

Table of Contents
loading

Table of Contents