4. On the initial refrigerator start-up, it may take
longer than 10 seconds to allow air to be purged
from the gas line. If gas does not ignite within 20
seconds, valve will automatically shut off and the
red X will be displayed at the CHECK position.
5. To restart when the X is displayed, move
AUTO-OFF-GAS switch to OFF position then
return switch to the GAS position.
Start Up Instructions - Auto Mode
A
CAUTION
82
AUTO OFT GAS ELEC CHECK GAS COLD COLDEST
DC
Eta. 1±.111±1
I DC
OPER
ATION
1. Move thermostat to COLDEST position. Set
AUTO-OFF-GAS switch to AUTO. Set DC
OFF/DC ON to DC OFF.
2. If 120 volts is active, Mode Control panel will
display AC, indicating refrigerator is operating in
120 volt AC mode.
3. If 120 volts AC is inactive (power failure, dis-
connected, etc.), Mode Control panel will dis-
play LP, indicating refrigerator has automatically
DO NOT CONTINUE TO RESET GAS SWITCH
switched to LP gas mode.
IF CHECK INDICATION CONTINUES TO DIS-
4. If Mode Control panel displays LP and a red X
PLAY AFTER SEVERAL TRIES. A GAS BUILD-
continuously, the refrigerator has failed to ignite
UP MAY OCCUR IN THE BURNER AREA AND
burner on gas mode. Restart gas operation by RESULT IN A FLASH BACK WHICH MAY
moving AUTO-OFF-GAS switch to OFF and CAUSE PERSONAL INJURY.
back to AUTO (See steps 3, 4, and 5 under
Gas Mode.). Note: Unit operation will automat-
ically return to AC when 120 volts AC is restored,
DC Mode
even if the unit is locked out on gas operation.
5. Move thermostat to desired setting, usually a
mid setting.
Start Up Instructions - Gas Mode
8F%
82
AUTO OFF GAS ELEC CHECK GAS COLD COLDEST
GAS
sk±1
'
1
OPERATION
1. Move thermostat to COLDEST. Set AUTO-
OFF-GAS switch to GAS. Set DC OFF/DC ON
to DC OFF.
2. Mode Control panel will display LP, indicating
LP gas mode (If LP is not displayed, check for
loss of DC supply voltage.). Initially, the red X
will be displayed for about 2 seconds; after
which, sparking will start at the burner and the
red X goes off.
3. After 10 seconds, the burner should be ignited
and operating normally.
1. Move thermostat to COLDEST position.
2. Set DC OFF/DC ON switch to DC ON. (DC ON
will override the AUTO-OFF-GAS switch.)
3. Mode Control panel will display DC, indicating
operation in DC mode.
Shut Down Instructions - All Modes
Short Duration: Set AUTO-OFF-GAS switch to OFF.
Set DC OFF/DC ON switch to
DC OFF.
Long Duration: Set NORMAL-STORAGE-HIGH HU-
MIDITY switch (located on divider be-
tween the two doors) to STORAGE.
16