Test Procedures; Initial Functional Check For Tcd989/J Xenium - Philips Xenium Dual Band Service Manual

Table of Contents

Advertisement

7.7.3
Plug the transformer unit into the main AC power sockets.
7.7.4
The battery charge symbol indicates the state of the charge process :
If the battery is totally discharged, the battery icon will show and start scrolling 2 to 3 minutes only after
connecting to the charger.

8.0 TEST PROCEDURES

8.1

Initial Functional check for TCD989/J XENIUM

8.1.1
Insert the Test Production Card into the SIM Reader at the back of the cellular phone and clip a charged
battery on the phone.
8.1.2
Press the «ON» button for 2 seconds at least and the LCD will show a message which contains information
of FA and 12NC. (see
8.1.3
Follow the instructions as mentioned below :
Step
1
2
3
4
Bars moving
Steady
Procedure
Press Key 1
Press Key 1 again
Press key 2
(Audio loop local effect)
Press key 2 again
Press key 3
Audio loop test (Speak to
Mic and listen echo from
Speaker)
Press key 3 again.
Press key 4 (LEDs Test)
Check for the Backlight
function in the same time.
Press key 4 again
-
means the battery is being charged
-
means the battery is fully charged
Observation
Continue Buzzer signal
Left corner displays 1
"LocalEffect"
" XX XX "
Left corner displays 2
"AUDIO xx xx xx "
"EEP x xx xx xx "
Left corner displays 3
Red and green LED blinking
Left corner displays 4
00
01
02
03